3

Installation and Maintenance   

TWINFAN CONTROL

Three Phase Fans
(1ph power for 
control unit
taken from Fan).

E       N       L        R       Y       B

          N      L1   L2    L3

3ph 400V 50Hz  supply

E       N       L        L      SL       L      FL     L1      L2       N       E         H

BL    RD    BK      Y   

RUN       FAULT

230V MAINS CONTROL

Link

Link

NET

 CT-AVI  

- Audible / Visual 

Indicator

connection

QUIETWIN FAN  Three phase

230V 

Switched Live

Connection

(twinfan operates

when live, remove 

link when used)

 Volt Free Contacts

Rated 230V 5A

(for run indication

if required)

Volt Free Contacts

Rated 230V 5A 

(for fail indication 

if required)

L1     L2      N                H

CONNECTION 
BOX IN FAN

4 core

& Earth

Cable

230V power to control

from fan only requires
N & L to be connected

to N & R

E       N       L        R       Y       B

          N     L1     L2     L3

 400V 3 ph 50Hz  supply

E       N       L        L      SL       L      FL     L1      L2       N       E         H

BL    RD    BK      Y   

RUN       FAULT

230V MAINS CONTROL

Link

Link

NET

 CT-AVI  

- Audible / Visual 

Indicator

connection

QUIETWIN FAN  Three phase

230V 

Switched Live

Connection

(twinfan operates

when live, remove 

link when used)

 Volt Free Contacts

Rated 230V 5A

(for run indication

if required)

Volt Free Contacts

Rated 230V 5A 

(for fail indication 

if required)

L1     L2      N                H

CONNECTION BOX IN FAN

4 core

& Earth

Cable

230V 1ph 50Hz supply

Three Phase fan units
(1ph power for control 
taken from independent
source)

Note: 

Installation must comply with
electrical regulations as detailed
on page 1 

Figure 5.

Figure 6.

Details of alternative supply
wiring to Mains Control

IMPORTANT NOTE:

(BELT DRIVE TWINFANS)

A link plug is factory fitted to match this

Twinfan Control to single phase twinfans

When using the Twinfan Control with a 

belt drive twinfan you must first remove 

this link plug which  is located on 

the circuit board.

 L   FL   L1  L2   N          H    BL RD BK  Y    RUN    FAULT

       FAN                               FAN UNIT                                           ICP                                     RR                   RF               

      LIVE

Remove this plug to allow
control of belt drive fans

Summary of Contents for CT-A

Page 1: ...ary cable access NOTE It is the responsibility of the installer to seal the cable entries and to maintain the IP rating of the unit Select a suitable surface mounting position and fix the main cas ing to it using the four case mounting holes provided fig 2 ISOLATE THE ELECTRICAL SUPPLY and make your main electrical supply and fan unit connections to the terminals inside as shown in fig 8 FEATURES ...

Page 2: ...o Control Single Phase application Three Phase application N L L SL L FL L1 L2 N H BL RD BK Y RUN FAULT Connection for speed control Link must be removed when using a speed control 1 phase fans only L1 L2 N H QUIETWIN FAN Single phase 230v MAINS CONTROL 230V 1 phase supply NOTE supply to fan is via the control Link Link NET CT AVI Audible Visual Indicator connection 230V Switched Live Connection t...

Page 3: ...Link NET CT AVI Audible Visual Indicator connection QUIETWIN FAN Three phase 230V Switched Live Connection twinfan operates when live remove link when used Volt Free Contacts Rated 230V 5A for run indication if required Volt Free Contacts Rated 230V 5A for fail indication if required L1 L2 N H CONNECTION BOX IN FAN 4 core Earth Cable 230V 1ph 50Hz supply Three Phase fan units 1ph power for control...

Page 4: ... the SL terminal inside the case WARNING Switching the unit OFF on the front panel Power button does not isolate the fan or the control Figure 7 Twinfan Control buttons Power Fail Fail Duty Share Fan 2 Fan 1 Explanation of the button functions Fan 1 Fan 2 Pressing either button selects that fan to run If there is a fan failure the fail indicator will remain illuminated even after the fail ure has ...

Page 5: ...witch off 4 Do not reset this particular switch retain as set by factory Figure 13 Function switches L SL P I R sensor or Light Switch BL RD BK Y RUN FAULT ICP RR RF A B C D A volt free relay is included to provide status if any fan is running Maximum load is 5amp 230V ac When a fan is running A B are connected When a fan has failed C D are connected Figure 11 Remote Run Remote Fail connections Re...

Page 6: ...mensions of equipment and the right is reserved to make such changes without prior notice Western Industrial Estate Caerphilly Mid Glam CF83 1XH United Kingdom Telephone 029 2088 5911 Facsimile 029 2088 7033 Email info nuaire co uk www nuaire co uk Leaflet No 670912 GP168 Installation and Maintenance TWINFAN CONTROL 5 ...

Reviews: