NuAire AXUS SVT Series Installation And Maintenance Download Page 1

AXUS SVT 

300

o

C for 2hr

High Temperature Impulse Axial Fans

Installation and Maintenance

Introduction

The Nuaire SVT impulse unit comprises a high temperature
axial fan with specially designed inlet and outlet attenuators
which, along with the fan unit, are encased in a Galvanised
steel acoustic enclosure.

Fan Coding Descriptions

SVT

1

(A-E)

1

2

3

1. AXUS Impulse fan
2. Case size
3. Impeller blade angle

The Nuaire SVT unit comprising fan/motor assembly, and 
inlet & outlet silencers shall be certified for high temperature
operation at 300

O

C for 2 hours, the range shall have been type

tested to EN12101-3.

The units shall be either 2 speed or inverter driven providing,
low speed for day to day environmental ventilation and one off
operation for emergency ventilation (S1 duty). They shall also 
be suitable for reversible operation.

Fully reversible options (i.e similar duty in both airflow 
directions) are available, please contact Nuaire for details.

The unit shall have a unique mounting bracket, which shall
enable the bracket to be positioned as a “first fix” component
with the unit being fitted as a “second fix” component, avoiding
possible mechanical damage.

The Nuaire SVT unit shall have inlet guards for safety purposes
and also to prevent debris being sucked through the fan. It also
has a specially designed airflow deflector to direct the jet
stream from the fan at the required angle sufficient to overcome
the natural buoyancy effect of the smoke.

EN12101-3 compliant, refer to EC certificate of conformity
10086-CPD-467873. 

Handling

Always handle the units carefully to avoid damage and 
distortion. If mechanical aids are used to lift the unit, 

spreaders should be employed and 
positioned so as to prevent the 
slings, webbing etc. making 
contact with the casing. 

Installation

Installation must be carried out by competent personnel in
accordance with the appropriate authority and conforming 
to all statutory governing regulations.

1) 

Fixing unit jig and brackets together

Check that you have 2 off support brackets (SVT-BRKT2)
along with the unit jig.  Attach the 2 brackets to the jig as
shown below in figure 2.

Figure 2. 

2) Fixing support brackets to ceiling

Using the four 30mm x 12mm slots in the top side of the two
brackets attach the jig and support brackets to the ceiling.

3) Remove the jig

Remove the jig so only the support brackets are in position on
the ceiling. (see figure 3).  

4) Fit main SVT unit to brackets

The SVT unit can now be raised up into position  between the
two support brackets on the ceiling and attached when required. 

1

Leaflet Number 671256 November 2006

Nuaire Limited

Western Industrial Estate Caerphilly  United Kingdom CF83 1NA

Telephone:  029 2085 8200   Facsimile: 029 2088 7033
Email: [email protected]   www.nuaire.co.uk

Support brackets (2 off)

Support brackets  
attach to jig

Unit jig

50mm

602mm

616mm ctrs

673mm

  
Attach  SVT unit to  
support brackets  
positioned 
on the ceiling

Figure 3.

Figure 1.

Figure 4.