NuAire AIRMOVER DSA Series Installation And Maintenance Manual Download Page 16

Installation and Maintenance  

AIRMOVER DSA AXIAL UNITS

3 YEAR WARRANTY

The three year warranty starts from the date of delivery and
includes parts and labour for the first year.

The labour element is subject to full, free and safe access to the
equipment as recommended by the CDM regulations.

The remaining two years covers replacement parts only.

NOTE:
Installation & Maintenance of the equipment must be as
directed in the instructions provided with the unit.

NB
If you have any comments or
queries on any of our products or
services please write to the Product
Information Manager at the main
address opposite

Western Industrial Estate, Caerphilly,

CF83 1XH  United Kingdom.  

Tel: 029 2088 5911  Fax: 029 2088 7033,     

Email: [email protected]

www.nuaire.co.uk

Leaflet No. 670972 

Technical or commercial considerations may, from time to time,

make it necessary to alter the design, performance and dimensions 

of equipment and the right is reserved to make such changes 

without prior notice.

16

Service 

As a manufacturer NuAire provides you with factory trained
Service Engineers.
Our Engineers are supported by a comprehensive range of
spare parts 'off the shelf'.
If you are an industrial or commercial user, you may be 
interested in details of NuAire's regular maintenance Service
Contracts. This is a worthwhile service that helps you get the
most from our products.
Our Service Department will be happy to give you more 
information.

Please telephone:   01222  858254

Controls Application Service (CAS) 

A team of Engineers and technicians is available to provide pre
and post order support.
We are on hand to provide help and advice from the most
basic use of any NuAire equipment to the more complex
applications, maximising on the versatility of our SMART and
NetLink 
control products.

Telephone:   029 2085 8585
Facsimile:   029 2085 8586

GP187

Summary of Contents for AIRMOVER DSA Series

Page 1: ...arefully to avoid damage or distortion Units are provided with four lifting eyes If spreaders are used they should be positioned as near the end flanges as possible and in such a way that slings or we...

Page 2: ...ttach silencers directly to the airmovers using bolts at the corners b For units being prepared for horizontal mounting attach the resilient mountings and mounting feet at the corner holes of the flan...

Page 3: ...ff Testing Remove the access panel from the Airmover Switch on the local isolator by others Run the fan just sufficiently long to ensure that it rotates Switch off During run down by observation throu...

Page 4: ...ance AIRMOVER DSA AXIAL UNITS Installation Vertical Mounting Fan unit Free air space Free air space Free air space Flow Flow Free air space Detail of resilient mounting onto steelwork Steelwork by oth...

Page 5: ...er Square Axial Code M8 unit fixings supplied Mounting Foot details Note Four mounting feet are supplied with each unit or silencer see main dimension drawings M8 fixing screws are included 65 25 50 4...

Page 6: ...11 11 21 32 Fan Size Dimensions mm A B C D E dia Weight kg Dimensions D ctrs Silencer A sq 4 Holes E dia B C overall DSA 500 DSA560 630 DSA Code Dimensions mm Weight kg A B C C D E Short Long Short L...

Page 7: ...l spigot Heat resistance is 132o C with excellent resistance to chemicals ozone oil and grease The connector is airtight waterproof and tested to BS476 Part 7 Dimensions mm Unit Code DSA A B C DSFX4 5...

Page 8: ...speed as required Replacement of Parts Isolation BEFORE COMMENCING MAKE SURE THAT THE AIRMOVER IS EXTERNALLY ISOLATED FROM THE ELECTRICAL SUPPLY Parts For the ordering of spare and replacement parts s...

Page 9: ...loosened in the hub and the assembly of impeller and bush can be drawn from the shaft Remove the screw and separate the impeller and bush Fitting a taperlock impeller to a motor Making sure that tape...

Page 10: ...cable entry When delivered fan units fitted with a permanent capacitor motor will have links fitted When used with a speed control one link must be removed and the motor wired as shown in the appropr...

Page 11: ...1 phase 50Hz supply T1 T2 X L N L N L2 N N L1 Speed Control TRANSFORMER 1 phase L N Fan unit Control To Starter Control Circuit where fitted NOTE Remove link between X L when using a speed control ST...

Page 12: ...8 37 EC Machinery Directive 93 44 EEC Amendment to the Machinery Directive Applied Harmonised Standards EN292 1 EN292 2 EN294 EN29001 Applied National Standards BS848 Parts One Two and Five Signature...

Page 13: ...ge Directive Applied Harmonised Standards E50081 1 EN50082 1 EN60204 1 EN60335 2 80 Basis of Self Attestation Quality Assurance to BS EN ISO 9001 BSI Registered Firm Certificate No FM 149 Signature of...

Page 14: ...orientation 4 2 Where installation accessories are supplied with the specified equipment eg wall mounting brackets They are to be used to support the equipment only Other system components must have s...

Page 15: ...15...

Page 16: ...y from time to time make it necessary to alter the design performance and dimensions of equipment and the right is reserved to make such changes without prior notice 16 Service As a manufacturer NuAir...

Reviews: