IMPORTANT

The installation must be carried out by qualified personnel in
accordance with the appropriate authority and conforming to all
statutory and governing regulations.

ISOLATION

Note that the unit must be provided with a means of
isolation (by others) for maintenance purposes etc.  
A suitable isolator can be supplied by NuAire on
request as a separate item.

Introduction

NuAire Airmover DSA  square cased fans are 
produced with duty sizes up to 3.7 m

3

/sec. and

incorporate an axial flow  impellers.
Casings are manufactured in galvanised steel with 
propriety flanges fitted to allow connection to 
ductwork. A full width access panel allows inspection
of the motor and impeller whilst still in duct. 
A full range of matching ancillaries is available 
including Silencers, Fan Guards, Resilient Mounting
Kits, Speed Controls and Flexible Connectors.
All NuAire Airmover DSA axials  are tested to BS848
in our BSI approved laboratories. This ensures all 
technical data is accurate, which means that units can
be specified with confidence

Description 

The units are produced in two sizes: 500mm dia and
630mm dia, coded DSA500 & DSA630. 
Silencers, flexible connectors, resilient mountings and
guards are supplied as optional extras. Short and long
versions of the silencer (SIL-S) & (SIL-L) are
available for each size. Speed controls are available for
most units.

Handling 

Equipment must be handled carefully to avoid damage
or distortion. Units are provided with four lifting eyes.
If spreaders are used, they should be positioned as near
the end flanges as possible and in such a way that slings
or webbing do not bear on the casing. Webbing, rope of
any other material must not be passed through units for
lifting  purposes.

Installation

General

The design and provision of complimentary ductwork
supports, etc., is the responsibility of others. Adequate
space, however, must be provided around the
unit / silencer combination to enable it to be easily
removed from the ductwork when required. It is also
important that the fan unit is mounted so that it is 
readily accessible. Provide adequate space around the
unit to allow for the removal and the replacement of
the impeller and motor via the access panel.

Installation 
and Maintenance

AIRMOVER

Square Cased Fans

DSA (Axial Flow)

NuAire Limited
Western Industrial Estate Caerphilly,  
CF83 1XH    United Kingdom
Telephone  029 20 88 5911
Facsimile No. 029 2088 7033
Email: [email protected]
www.nuaire.co.uk

Leaflet No. 670972
OCTOBER  2001

Contents

Introduction  .............................................................   1

Description  ...............................................................   1

Handling  ...................................................................   1

Installation  ...............................................................   1

Motor Information   ................................................   3

Mounting arrangements ........................................   4

Dimensions  ...............................................................  6

Routine Maintenance  .............................................  8

Replacement of parts ..............................................   9

Speed Controls (single phase)...............................  10

Wiring diagrams .......................................................  11

Certification  ............................................................  12

1

Fig. 1    DSA in horizontal application.

W

ARNING

!

1.

D

O NOT REVERSE IMPELLER DIRECTION FOR

OPERATION AS THE PERFORMANCE OF THE UNIT

IS DRASTICALLY REDUCED

.

2.

D

O NOT ALTER THE BLADE ANGLE OF THE

IMPELLER WITHOUT THE PERMISSION OF

N

U

A

IRE

.

T

HE ABOVE MAY INVALIDATE YOUR WARRANTY

Summary of Contents for AIRMOVER DSA Series

Page 1: ...arefully to avoid damage or distortion Units are provided with four lifting eyes If spreaders are used they should be positioned as near the end flanges as possible and in such a way that slings or we...

Page 2: ...ttach silencers directly to the airmovers using bolts at the corners b For units being prepared for horizontal mounting attach the resilient mountings and mounting feet at the corner holes of the flan...

Page 3: ...ff Testing Remove the access panel from the Airmover Switch on the local isolator by others Run the fan just sufficiently long to ensure that it rotates Switch off During run down by observation throu...

Page 4: ...ance AIRMOVER DSA AXIAL UNITS Installation Vertical Mounting Fan unit Free air space Free air space Free air space Flow Flow Free air space Detail of resilient mounting onto steelwork Steelwork by oth...

Page 5: ...er Square Axial Code M8 unit fixings supplied Mounting Foot details Note Four mounting feet are supplied with each unit or silencer see main dimension drawings M8 fixing screws are included 65 25 50 4...

Page 6: ...11 11 21 32 Fan Size Dimensions mm A B C D E dia Weight kg Dimensions D ctrs Silencer A sq 4 Holes E dia B C overall DSA 500 DSA560 630 DSA Code Dimensions mm Weight kg A B C C D E Short Long Short L...

Page 7: ...l spigot Heat resistance is 132o C with excellent resistance to chemicals ozone oil and grease The connector is airtight waterproof and tested to BS476 Part 7 Dimensions mm Unit Code DSA A B C DSFX4 5...

Page 8: ...speed as required Replacement of Parts Isolation BEFORE COMMENCING MAKE SURE THAT THE AIRMOVER IS EXTERNALLY ISOLATED FROM THE ELECTRICAL SUPPLY Parts For the ordering of spare and replacement parts s...

Page 9: ...loosened in the hub and the assembly of impeller and bush can be drawn from the shaft Remove the screw and separate the impeller and bush Fitting a taperlock impeller to a motor Making sure that tape...

Page 10: ...cable entry When delivered fan units fitted with a permanent capacitor motor will have links fitted When used with a speed control one link must be removed and the motor wired as shown in the appropr...

Page 11: ...1 phase 50Hz supply T1 T2 X L N L N L2 N N L1 Speed Control TRANSFORMER 1 phase L N Fan unit Control To Starter Control Circuit where fitted NOTE Remove link between X L when using a speed control ST...

Page 12: ...8 37 EC Machinery Directive 93 44 EEC Amendment to the Machinery Directive Applied Harmonised Standards EN292 1 EN292 2 EN294 EN29001 Applied National Standards BS848 Parts One Two and Five Signature...

Page 13: ...ge Directive Applied Harmonised Standards E50081 1 EN50082 1 EN60204 1 EN60335 2 80 Basis of Self Attestation Quality Assurance to BS EN ISO 9001 BSI Registered Firm Certificate No FM 149 Signature of...

Page 14: ...orientation 4 2 Where installation accessories are supplied with the specified equipment eg wall mounting brackets They are to be used to support the equipment only Other system components must have s...

Page 15: ...15...

Page 16: ...y from time to time make it necessary to alter the design performance and dimensions of equipment and the right is reserved to make such changes without prior notice 16 Service As a manufacturer NuAir...

Reviews: