page
17
DOOR TEST PROCEDURE:
A. Cut one or two strips of paper (do not use deli paper) approximately 1" wide and 8" - 10" long.
B. Open the door slightly, insert a strip of paper between the gasket and door and close the door.
C. Slowly pull the paper strip out. You should feel some resistance as you pull the strip from between the
gasket and door of a properly adjusted door. Test the fit at regular 2" to 3" intervals around the entire
Door.
1.
If you feel NO resistance at a particular spot the door is too loose.
2.
If you feel HEAVY resistance at a particular spot the door is too tight.