background image

 

 

Page 1 of 4  

 

 

 

     

 

 

 

 

Unit 4, Kimpton Trade & Business Centre 

Minden Road, Sutton, Surrey, SM3 9PF

 

 

Tel: 020 8254 6802

 

 

Fitting & Operating Instructions For The Thermatronic Radio 

Frequency Electronic Control System (Mertik Maxitrol) 

 
 

 

 

 
 
 
 

 
 
 
 
 
 
 

 
 

 
 

 

 
 

 

 

 

 

 
 
 
 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
General

 

 
 

 
 

Important Notes 

 

Temperature Limits of Electronic Components 

It absolutely necessary to ensure that the electronic control system components temperature do not rise above 60ºC. 

 

For Hole In The Wall installations (sunken burners) see the attached sketch showing our suggested installation arrangement.  If you keep 
to air inlet and outlet free areas of 100cm

2

 each and ensure that the void under the fire is properly backfilled (to avoid flue pull under the 

burner) then, assuming a normal room temperature, the temperature of the electronic components should not rise too much above 30ºC.  
This allows a big margin of safety. 

 

It is also very important to ensure that the fire is not subjected to intermittent flue downdraught, which can blow flames/gas down to the 
underside of the burner and cause overheating of the electronics. 

 

Batteries  

For Hole In The Wall installations (sunken burners) the fire is supplied with batteries in a separate box that has a long lead which plugs 
into a socket on the standard electronics/battery box.  This allows the batteries to be placed in an accessible place such as behind the air 
inlet grille, as shown on the installation sketch. 

 

If using the extended battery box ensure that any batteries are removed from the electronics box battery compartment.  This battery box 
is  available  as  an  optional  extra  for  other  installations,  if  required.  Also  available  as  an  optional  extra  is  a  mains  adaptor  to  be  used 
instead  of  batteries,  which  again  has  a  long  lead  which  plugs  into  the  socket  on  the  standard  electronics/battery  box.  IMPORTANT 

– 

BATTERIES MUST BE REMOVED BEFORE USING THE ADAPTOR. 

 

Dampness  

All electronic equipment is sensitive to dampness and high humidity.  The Thermatronic equipment must be installed in a completely dry 
place that does not access directly to outside air.  If the fireplace has recently been rendered it must be allowed to completely dry out 
before  the  electronic  equipment  is  installed.    It  is  possible  that  dampness  has  occurred  during  storage  of  the  appliance,  so  as  a 
precaution we suggest placing the electronic box in a warm dry place for a while before installation. 

 

Gas Supply 

In common with all other gas appliances, dirt and debris in the gas system can block the valve and gas injectors on this appl iance, and 
faults caused by this are not covered by the guarantee.  Pipework installation must comply with approved standards and practices.  If in 
doubt as to the cleanliness of site pipework, install a sediment trap, or filter as close to the appliance as possible

 

Resetting the Mertik Maxitrol Logic Circuits (Radio Frequency Control) 

 

BASIC RESET 

It  sometimes  happens  that  (such  as  when  the  handset  buttons  are  pressed  out  of  sequence)  the  fire stops  working because  the logic 
circuits get confused and need to be reset. To do this, simply remove the 4 x AA batteries from the Receiver Box (do not use  metal tools 
to  do  this),  wait  for  1  minute  and  then  refit  the  batteries. Wait  for  another  minute  and  then  point  the  handset  at  the  fire  and  press  the 
red/off button. Wait for another minute and then start the fire as normal. If the fire does not start repeat the resetting procedure. If the fire 
still does not work a Full Reset can be tried (see below). 

 

Note: If an extended battery box has been supplied, and the lead has been unclipped from the battery box, do not let the lead terminals 
touch any metal parts, because voltage is still stored in the capacitors, which can cause a short circuit. 

 

FULL RESET 

– TO BE USED IF A REPLACEMENT HANDSET IS OBTAINED 

 

NOTE. On some burners such as the Fireboxx and 

“sunken” burners it is not possible for the user to access the Receiver Box 

to carry out a Full Reset.  If the user cannot access the reset button on the Receiver Box a Qualified Installation Engineer will 
need to remove the burner to do so and this will involve disconnecting the burner from the gas supply. 

 

If  you  obtain  a  new  hand

set  the  control  system  will  need  to  learn  the  handset’s  unique  code  via  a  Full  Reset.  Also,  if  the  fire  is  not 

working and the Basic Reset (described above) has not worked a Full Reset can be carried out: 

 

a. 

Replace the batteries in the Receiver and Handset. 

b.

  Locate the Reset Hole on the side of the Receiver and using a pen press and hold in the Reset button until you hear two beeps. 

      The first beep is short and the second beep is long. After the second beep release the Reset Button. 

c.

  Now on the Handset, within the next 20 seconds press the Small Flame Button until you hear two additional short beeps  

      confirming the code is set in the Receiver.  

d.

  If you hear one long beep the Code as not been set so repeat the procedure. 

e.

  If the fire still does not work, the problem lies elsewhere. 

 

Note: If an extended battery box has been supplied, and the lead has been unclipped from the battery box, do not let the lead terminals 
touch any metal parts, because voltage is still stored in the capacitors, which can cause a short circuit. 

 
 
 
 
 
 

IMPORTANT NOTE 

 

THIS APPLIANCE MUST BE INSTALLED & SERVICED BY A 

PROPERLY QUALIFIED (IN ACCORDANCE WITH LOCAL & 

NATIONAL CODES) GAS INSTALLATION ENGINEER. 

 

THESE INSTRUCTIONS ARE FOR THE FIRE’S CONTROL SYSTEM 

ONLY, AND MUST BE USED IN CONJUNCTION WITH THE 

INSTALLATION INSTRUCTIONS FOR THE GAS FIRE.

 