background image

  

 

 

 
 

 

FENTON CONVENTIONAL FLUE  

 

CONVENTIONAL FLUE OUTSET CONVECTION HEATER  

SUITABLE FOR NATURAL GAS & PROPANE 

 

USE, INSTALLATION & SERVICING INSTRUCTIONS 

 
 

The glass panel and outer parts of this fire will become hot during use, cloths or combustible items 

must not be placed close to or on the fire. We recommend that a Fireguard conforming to BS8423 

should be used for protection of Young Children the Elderly, Infirm and Pets. 

 
 
 

ALL INSTRUCTIONS MUST BE LEFT WITH THE USER FOR 

SAFE KEEPING 

 

 
 

MANUFACTURED by: 

Nu-Flame Limited 

Unit 4, Kimpton Trade & Business Centre 

Minden Road, Sutton, Surrey SM3 9PF 

Tel: 020 8254 6802 

Fax: 020 8641 9992 

Email: [email protected] 

 

Country of Destination – GB & IE 

 

 

 

Revision 27.2.20 GAR 

Summary of Contents for FENTON CF

Page 1: ...t not be placed close to or on the fire We recommend that a Fireguard conforming to BS8423 should be used for protection of Young Children the Elderly Infirm and Pets ALL INSTRUCTIONS MUST BE LEFT WIT...

Page 2: ...Declaration of Conformity 32 22 Diagram of Thermatronic Radio Frequency Control System 33 Guarantee 34 BOX CONTENTS The Fire comes in a number of boxes Box 1 Large box contains the Fire the Matrix Tr...

Page 3: ...bove 2 No6 x 5mm blunt self tapping screws for fixing the Case 1 10mm Back Nut olive to connect 8mm copper pipe gas supply to the burner via the isolation elbow 1 2 1 metre length of 6mm x 4mm self ad...

Page 4: ...is the appliance must be serviced q Coal Wood Effect Parts are manufactured from RCF Refractory Ceramic Fibre are supplied with this appliance see Health Safety guidance Do not use real coals or wood...

Page 5: ...mmand has been received and the push button should immediately be released to allow the control to operate Using the Thermatronic Remote Control System Control can only be achieved if the Handset is p...

Page 6: ...e Small Flame button to set the Minute Press Off or simply wait to return to the manual screen IMPORTANT For the following modes of controlling the fire automatically for Temperature or Timer Programs...

Page 7: ...ty alkaline e To change the Handset battery slide open the plastic panel on the back of the Handset f To change the Receiver Batteries remove the Ash Pan Cover and locate the electronic receiver box u...

Page 8: ...ss panel d The outer surfaces of the fire can be cleaned with a damp cloth do not use any abrasive cleaners For Stainless Steel finishes we recommend a small amount of Baby Oil IMPORTANT The Fire Must...

Page 9: ...efficient fire may be more suitable or flue lining may need considering d Take account of the fire previously fitted and if the heat output will be sufficient for the room size and heat requirements...

Page 10: ...ALLATION READ THESE INSTRUCTIONS CAREFULLY THESE INSTRUCTIONS SHOULD BE LEFT WITH THE USER FOR SAFE KEEPING AND FUTURE SERVICING PRIOR TO INSTALLATION ENSURE THAT THE GAS TYPE AND PRESSURE ARE AS STAT...

Page 11: ...Test see Section 18 2 b For other Countries refer to National Regulations and Local Codes c This appliance is fitted with an oxygen depletion sensing system which automatically shuts off the gas suppl...

Page 12: ...lace opening Sections 11 13 are for the various Installation Applications Only one will apply IMPORTANT NOTE The chosen installation should have been predetermined and arranged before installing the f...

Page 13: ...t which is sensitive to dampness and high humidity so it is very important that any rendering building work is allowed to thoroughly dry out before Installation IMPORTANT NOTE Dry lined walls ensure t...

Page 14: ...FLUE Fire Surround Requirements Pre Cast Flue Application With Fire Surround or Equivalent Pre Cast Fireplaces Minimum Requirements 65 Min Fire Surround Back Panel 630 min 470 max 300 min 630 min 65mi...

Page 15: ...seal between the face of the surround and the sealing flanges of the fire l The Fireplace Opening should have provision for a gas supply through the rear see Section 10 Gas Supply m The Thermatronic...

Page 16: ...ip must extend up to the underside of the shelf a A suitable BS715 Shallow Flue Box should be used with the minimum dimensions quoted above b The base of the Flue Box must be level and square to the f...

Page 17: ...ensitive to dampness and high humidity so it is very important that any rendering building work is allowed to thoroughly dry out before Installation IMPORTANT NOTE Do not forget to take account of the...

Page 18: ...at the Bottom Left and Right corners Securing the Glass Frame and ease it outward slightly at the base then pull down and remove IMPORTANT NOTE TAKE GREAT CARE WHEN WORKING INSIDE THE FIRE NOT TO MAR...

Page 19: ...nd Lock Screw can now be fitted through the hole in the Back Box onto the cable and tightened up to tension the fire back into the fireplace The fire should be secure and not liable to movement Surplu...

Page 20: ...he Front Moulded Coal into positions between Front Heat Shield and Burner as shown Health Safety Advice Refractory Ceramic Fibre RCF Advice when working with Fuel Bed Components including Installing S...

Page 21: ...a flat side up against the back and the other down on to the Rear Coal Then place the others either side leaning against the centre Coal as shown d Take 2off J coals and place either side of coals jus...

Page 22: ...Front LH RH corners as shown h Fit 3off J Coals along the front on top of those fitted earlier as shown h Fit 2off small G Coals along the front one either side of those just fitted as shown h Finally...

Page 23: ...ion of the glass and also ensure it is clean and free from any finger marks Note The glass is etched with the Nu Flame logo and the glass is to be positioned with the logo in the bottom right hand cor...

Page 24: ...fitted as shown Ensure the lug extended under the Wood Piece is located into the Cavity in the Front Wood Piece e Fit No 3 Wood Piece in the Centre as shown f Fit No4 Wood Piece to the right of the wo...

Page 25: ...he 2 screws and screw driver provided check the condition of the glass and also ensure it is clean and free from any finger marks Note The glass is etched with the Nu Flame logo and the glass is to be...

Page 26: ...ove The majority of the smoke must be drawn into the duct Some small whiffs of smoke may be expelled and this is quite normal Be careful not to introduce too much smoke i e by using a pellet A smoke m...

Page 27: ...peration of the fire 18 1 GENERAL Note Servicing must be carried out by a registered installer a The fire does not have to be removed for Servicing however you will need to remove the Case as detailed...

Page 28: ...ime and or gas control Refer to Section 22 for Cable connections diagram 19 3 PILOT GOES OUT AFTER FIRST LIGHTING a Check there is no debris blocking the flame to the thermocouple b Check the thermoco...

Page 29: ...eographical location and so if a Flue Problem is thought likely but no problem is found during the investigation isolate the fire and seek expert advice 19 8 THERMATRONIC RADIO FREQUENCY CONTROL SYSTE...

Page 30: ...e must be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame Limited Mode...

Page 31: ...st be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame Limited Model Fe...

Page 32: ...ect of the declaration described above is in conformity with relevant harmonized legislation Gas Appliance Regulation EU 2016 426 The following harmonised standards and technical specification have be...

Page 33: ...33 22 DIAGRAM OF RADIO FREQUENCY CONTROL SYSTEM...

Page 34: ...rn delivery to us We will not be liable for any such breakages Under no circumstances should any attempt be made to repair the burner on site without our express knowledge and approval during the warr...

Reviews: