Rev 6.1 November 1, 2016
17
3.2.1.2.
Win-1
3.2.1.3.
Win-20
UNI
T
2
4
VAC
R
E
MO
VAB
L
E
T
E
R
MI
NAL
B
L
OC
K
NC
I
NO
R
C
TL
TS
SB
Hi
LO
RED
GREEN
BLACK
YELLOW
WIN-1
Choose from the following operating modes:
1. Off
2. Standby
3. Continuous low speed
4. Intermittent high speed
5.
Continuous high speed (CONSTANT)
UNI
T
2
4
VAC
R
E
MO
VAB
L
E
T
E
R
MI
NAL
B
L
OC
K
N
C
I
NO
R
C
TL
TS
SB
Hi
LO
PWR (red)
LED (yellow)
SWITCH
(black)
WIN-20
Up to 6 Win-20 timers may run off of one system.
WIN-20 can be combined with ES Series controls or
24V controls discussed in this document.
For Win-20-2 wiring, R and TS terminals are used.
If you are using
ONLY
a
WIN-20(s)
to control your
unit, you must connect a jumper wire between R and
SB on the 24V (10-wire) removable terminal block.
In this situation you can add continuous low speed
operation by connecting a jumper wire between R
and LO. Consult local building code in case a
centrally located control with an on/off switch is
required.