background image

 
 
 
 
 

 

 

 

GmbH • St-Korbinian-Str. 8 • D-83626 Valley • Telefon 08024/50 37 • Fax 4 99 44 • www.ntt-valley.de • [email protected] 

 

 

 

 

 

3

 

 

 

 

-Universal Attachment  

Guidance for installation and application 

 

1. 

Operating instructions for TOPPAS universal attachment 

 

1.1

 

Device identification 

 

 

Manufacturer: 

 

 

 

ntt GmbH 

St-Korbinian-Str. 8  

D-83626 Valley 

 

 

 

 

1.2

 

General information 

 

 

Operating instructions for TOPPAS and TOPPAS universal attachment as well as the video are regularly 
updated and can be downloaded from our Homepage. 

 

The customer/reseller of TOPPAS must ensure that the latest version of these instructions to users and 
operating companies and the video are provided to the end customer, the in-charge and users of TOPPAS 

and TOPPAS universal attachment, and that they have understood and will follow these instructions. If 

required, these instructions and the video can be provided in the language of a particular country. The 

name of the end customer must always be notified to us. 
The end customers must be able to handle TOPPAS universal attachment properly. Please contact ntt for 

information and training courses. 

 

The regular attachment of the TOPPAS universal attachment, the correct selection of the attachment place 

and proof of the load-carrying capacity of the materials (wall, ceiling, etc.). the means of mounting as well 

as the selection, attachment and protection of the positioning rope is incumbent on the buyer, operator or 

authorization. 

 

 

 

1.3

 

Intended use of TOPPAS universal attachment 

 

 

The TOPPAS universal attachment must be used for the intended purpose only in the technically flawless 

condition. 

In case of faults or damage, the operation of the TOPPAS universal attachment must be 

stopped immediately and ntt must check it. 

 

The operating company must ensure that the usage instructions are understood and followed. 

 

The supplier/manufacturer shall not be responsible for damage caused due to improper usage or 

modification.  

 

The universal attachment must be installed horizontally or vertically. 

 

Deviating installation positions, modifications or additions to the device unit must be checked and approved 

by ntt in writing. 

 

When planning, always ensure that the proper drawing function of TOPPAS is assured and implemented.  

 

The TOPPAS universal attachment must be planned and installed properly. The substructure and structural 
devices such as wall and roof materials must withstand the induced total force of 8 kN or 7 kN per fixing 

point (dowel, screw) and must have at least twice load-bearing capacity. 

 

Fixing aids, screws, nuts and dowels and their materials must be adapted for the application case and the 
installation situation and must have an approval certificate. 

 

Cable inlet and outlet of TOPPAS must always be linear and take place in-line or centrally. 

 

The TOPPAS universal attachment must be installed at such a distance from the climbing wall that cable is 
not deflected 

 

Climbing grips must be positioned and selected such that only minor cable deflection is possible in all 
directions, especially upwards. This should avoid impacts and oscillations especially in the upper section of 

the wall. 

 

When installing and dismantling TOPPAS, always secure using the positioning cable until the ball lock pin is 
inserted. 

 

Insert the ball lock pin into the hole of the axis from top and secure additionally using the securing screw. 

 

ntt or an expert must check the brackets and especially the bearing points, screw joints, safety connectors, 
etc. for functional capability at least during the annual check. 

Summary of Contents for TOPPAS

Page 1: ...ral information 3 1 3 Intended use of TOPPAS universal attachment 3 1 4 Installation examples 4 1 5 Fixing the TOPPAS universal attachment 5 2 Installing and dismantling TOPPAS with the positioning ca...

Page 2: ...eplacement and repairing of parts detected as defective by ntt 3 For checking the complaints and repairs please send the TOPPAS Universal attachment to the address of ntt ntt shall not bear any costs...

Page 3: ...ersal attachment must be stopped immediately and ntt must check it The operating company must ensure that the usage instructions are understood and followed The supplier manufacturer shall not be resp...

Page 4: ...0 10 27 109 72 498 30 mit H lle 32 304 181 21 25 1170 Optimum cable inlet and outlet Main axis cable guide Highest grip 15 main axis Smallest and most difficult top grips 15 30 30 Delimitation sector...

Page 5: ...the balls Secure the connector using the securing screw and the size 4 Allen key such that it is hand tight It can be dismantled in the reverse order The installation position of TOPPAS with respect t...

Page 6: ...antling as well Prerequisites The positioning cable length must be at least 3 times the installation height of TOPPAS We recommend a slip proof mountaineering rope 9 mm Another person to lift TOPPAS S...

Page 7: ...S up to the height of the installation position Secure the positioning cable against slackening using the cable clamp Then slide TOPPAS over the locking pins note do not forget bushes brake shows forw...

Reviews: