Operation
The DX32R is operated via the Network port using the Penta manager control program, DADman control
programme or via the NTP Router Control System RCCore, when the unit is a part of an integrated routing
system. On the front panel there are LED indicators showing the status of the unit, and on the rear panel
there is “
reconfig
” button by which the unit can be set into certain pre configured modes.
Front panel LED’s
DX32R has 3 LED indicators on the front panel. The indicators are
Ready, Error
and
PSU OK.
The function
of the indicators are described below.
Ready
ON
Green LED indicates that the unit is operative, and
all software is loaded and OK.
Ready
BLINK
Green LED blink indicates that the unit is in reconfig
mode
Error
ON
Red LED indicates a hardware error on the unit.
This could be an I/O card that is not working, a fan
fault or a PSU error. A detailed report will be in the
alarm log of the control software. In normal
operation the LED is off.
PSU OK
ON
Green LED indicates that the power supplies are
OK.
PSU OK
BLINK Green LED blink indicates that one of the two
power supply is not OK or absent.
Reconfig button
The “
reconfig
” button is accessed via a hole in the rear panel using a pen or a similar pointed item. Trough
the hole a green LED is visible, which will light up indicating the various reconfig modes of the DX32R as a
result of the activation of the “
reconfig
” button. When DX32R is in recovery mode the
Ready
Led on the front
panel of the unit will blink.
Recovery mode
“reconfig
”
push while the
unit is powering
up
Green LED
turns ON
The DX32R enters a recovery mode. In this mode
only a basic boot code is operative in the unit, and
new code can be downloaded by the NTP
download software. This mode is used if the
software on the platform for some reason is not
operative.
The IP address of the unit is the one currently
used and stored in the internal EERPOM
“reconfig
”
short push
while the unit is in
reconfig mode
and Green LED is
on
Green LED
turns OFF
The DX32R remains in reconfig mode as
described above.
The IP address of the unit is however
the default
address 10.0.7.20
, and IP discovery is set to
DHCP which will change the IP address if a DHCP
server is available in the network