P3245-1M
Multimeter digital, True RMS
20
5.
Technical Specifications
The accuracies indicated in the table below are related to standard conditions of
18 … 28
℃
and a relative humidity of less than 80%.
Function
Measurement Range
Resolu-
tion
Accuracy
DC
Voltage
(V)
mV 60.00mV/600.0mV
0.01mV
±(0.5%+2dig)
V
600.0mV/6.000V/60.00V/600.0V 0.1mV
V
1000V
1V
±(0.8%+2dig)
AC
Voltage
(V)
mV 600.0mV
0.01mV ±(0.8%+3dig)
V
600.0mV
0.1 mV ±(2%+5dig)
V
6.000V/60.00V/600.0V
1mV
±(0.8%+3dig)
V
750V
1V
±(1%+3dig)
DC
Current
(A)
μA 600.0μA/6000μA
0.1μA
±(0.8%+2dig)
mA 60.00mA/600.0mA
0.01mA ±(0.8%+2dig)
A
20.00A
[1]
0.01A
±(1.2%+3dig)
AC
Current
(A)
μA 600.0μA/6000μA
0.1μA
±(1%+3dig)
mA 60.00mA/600.0mA
0.01mA ±(1%+3dig)
A
20.00A
[1]
0.01A
±(1.5%+3dig)
Resistance (Ω)
600.0Ω/6.000kΩ/60.00kΩ/
600.0kΩ/6.000MΩ
0.1Ω
±(0.8%+2dig)
60.00MΩ
0.01 MΩ ±(2%+3dig)
Capacitance
(F)
60.00nF/600.0nF/6.000μF/
60.00μF
0.01nF ±(3%+3dig)
600.0μF/6.000mF/60.00mF
[2]
0.1μF
±(3%+5dig)
Frequency
[3]
(Hz)
9.999Hz/99.99Hz/999.9Hz/
9.999kHz/99.99kHz/999.9kHz/
9.999MHz
0.001Hz ±(0.8%+2dig)
Duty Cycle
[4]
(%)
0.1% - 99.9%
(Typical
:
Vrms=1 V, f=1 kHz)
0.1%
±(1.2%+3dig)
0.1% - 99.9%(
≥
1 kHz)
±(2.5%+3dig)
Temperature
(°C/°F)
-
50
℃
to 400
℃
1
℃
±(2.5%+3dig)
-
58
℉
to 752
℉
1
℉