COMMAND MODE 

 

The XTENDEX has two areas of user control that can be used as needed.     The user can adjust video quality (described 
below) ,   or enable/disable MAC mode (see page 11)    These controls are accessed by entering Command Mode.    
 
To enter Command Mode,  simultaneously press the left and right <

Shift

> keys on the keyboard connected to the Remote 

Unit.   The keyboard LEDs will illuminate.   
 
To exit Command Mode,  press <

Esc

>.  

 
 
                                                           
 

Automatic Video Quality Adjustment  

 

(ST-C5USBVA-300 only) 

 
Video quality adjustment is done automatically to assure the image is as clear as possible.    

 
Note: If a different type of cable is used (i.e. shielded cable) and the image is not crisp and clear, there may be a need for 
fine adjustment.. For fine adjustment, follow the same procedure as described under “Manual Video Quality Adjustment”  
below. 

 

 

Manual Video Quality Adjustment

 (ST-C5USBV-300 only)

 

 

 

It is possible that on initial startup the image on the monitor will not be as crisp as the image normally is. This is due to the 

frequency characteristics of the CAT5 cable.    It may be necessary to enter Command Mode (described above) and press 
the   

 (

up arrow

)  or   

(

down arrow

) keys on the remote keyboard until the image is crisp and clear.   

 

 

Press  

 (

up arrow

) key if the image is not crisp and clear enough.     

 

 

Press the  

(

down arrow

) key if the image has been over-corrected (such that horizontal lines appear to trail or  

shadow at the edge of an open window).    

 

 

A momentary press of either key will make a minor change in the image.   

 

 

Ultimately, the image quality should improve to a satisfactory level.   Once the adjustment is made, it should not be necessary to 
change it again, as the new settings are stored in memory and become the default settings with each startup.   To exit Command 
Mode,  press <

Esc

>.  

 

Note:  For additional quality adjustment, it may be necessary to adjust the brightness and contrast settings of the 
monitor.  

 

Note:  The video quality adjustment procedure can only be performed from the keyboard connected to the Remote Unit.  

 
 

Summary of Contents for XTENDEX ST-C5USBV-300

Page 1: ...SBV 300 ST C5USBVA 300 300 FOOT USB KVM EXTENDER Installation and Operation Manual XTENDEX Series NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202 www...

Page 2: ...Danner Drive Aurora Ohio 44202 For more information please contact Network Technologies Inc at 800 742 8324 800 RGB TECH or 330 562 7070 CHANGES The material in this guide is for information only and...

Page 3: ...15 SUN s 16 Extra Keys 15 Troubleshooting 17 Index 18 Warranty Information 18 Table of Figures Figure 1 Connect the Local Unit to a CPU 5 Figure 2 Local unit with audio support connects to CPU 6 Figu...

Page 4: ...1024 60Hz 300 feet 1280 x 1024 60Hz 150 feet 1600 x 1200 60Hz 150 feet 1600 x 1200 60Hz 100 feet 1920 x 1440 60Hz 100 feet Video quality is easily adjusted using keyboard controls Installation can be...

Page 5: ...0VAC or 240VAC 50 or 60Hz 9VDC 1A AC Adapters 9 CD with a pdf file of this owner s manual Additional materials may need to be ordered depending upon the configuration Video adapter for connection betw...

Page 6: ...CPU 6 9VDC connection jack for AC adapter 7 Audio Jack 3 5mm stereo audio jack for connecting to local speakers ST C5USBVA 300 only 8 Monitor 15HD female for connection of video cable from local monit...

Page 7: ...the Remote and Local Units A properly grounded polarized and preferably surge protected 120V or 240V electrical outlet depending on the AC adapter being used must be installed close enough to the moun...

Page 8: ...on the CPU first and then connect the video cable to the adapter Figure 1 Connect the Local Unit to a CPU c If the Local Unit has Audio support ST C5USBVA 300 only connect the black 3 5mm stereo plug...

Page 9: ...it BLUE VIDEO USB CPU BLACK AUDIO 3 5mm Stereo Plug AUDIO CONNECTOR line out ONE WILL BE MARKED line out spkr headphones OR WITH THIS SYMBOL USB Type A male 15HD male Video Connector Rear View XTENDEX...

Page 10: ...Connect the CAT5 cable to the Local Unit The Remote Unit Connect the Remote Devices Position the Remote Unit such that the CAT5 cable the monitor cable the keyboard and mouse and the AC adapter power...

Page 11: ...mote Unit Front View NTI R Network Technologies Inc XTENDEX USB 3 5mm Stereo Audio Jack Stereo Speakers ST C5USBVA 300 Remote Unit VGA Multi Scan Monitor 15HD Female Video Connector CAT5 Cable to Loca...

Page 12: ...ctors to the 9VDC ports on the Remote and Local Units AC adapter shown in Fig 9 3 Plug the AC adapters into power outlets The Power LED Green on the CAT5 connector of each unit should illuminate indic...

Page 13: ...l startup the image on the monitor will not be as crisp as the image normally is This is due to the frequency characteristics of the CAT5 cable It may be necessary to enter Command Mode described abov...

Page 14: ...e is ON See Fig 10 3 To reconnect the XTENDEX to a SUN or Windows CPU the default setting press the W key and the MAC LED will go OFF Figure 10 MAC LED After setting the configuration is stored in mem...

Page 15: ...BETWEEN CPU AND MULTI USER MATRIX SWITCH STANDARD APPLICATION BETWEEN USERS AND CPU BETWEEN SINGLE USER KVM SWITCH AND USERS USB Mouse USB Keyboard USB Mouse USB Keyboard USB Keyboard USB Mouse USBVE...

Page 16: ...ertical Frequency Range 30 Hz to 150 Hz Keyboard Mouse Connectors USB Type A female to local and remote keyboard mouse USB Type A male to CPU Interconnect Cable CAT5 5e Solid UTP STP EIA TIA 568B wiri...

Page 17: ...R 3 White Green 3 T 4 Blue 1 R 5 White Blue 1 T 6 Green 3 R 7 White Brown 4 T 8 Brown 4 R Figure 12 Pin positions in female RJ45 connector Note CAT5 connection cable used between NTI XTENDEX Series L...

Page 18: ...t Windows Logo Command Meta SB R Arrow SB R Arrow Power Suspend SB Space Bar L and R Left and Right keys when two keys are marked the same on a keyboard SUN s 16 Extra Keys Use the chart below to type...

Page 19: ...e Break Print Screen SysRq Application Key Windows Logo Key Windows Logo Key Enter Return Alt Graph Shift Shift Control Tab Capslock Alt Backspace Num Lock Help Stop Props Front Open Find Cut Paste Co...

Page 20: ...ify length is within specified limits 300 Check cable connections Make sure they are snapped in properly and completely See pg 10 for instruction on Video Quality Adjustment Monitor sometimes loses sy...

Page 21: ...of purchase Please contact Network Technologies Inc at 800 742 8324 800 RGB TECH or 330 562 7070 or visit our website at http www networktechinc com for information regarding repairs and or returns A...

Reviews: