Tft Series Installation and Operation Instructions
│
Trinity
75
Table 16-3
Hold and Lockout Codes
Code
Description
Note
215
Invalid Purge rate proving setting
Lockout
216
Invalid Run flame failure response setting
Lockout
217
Invalid Run stabilization time setting
Lockout
218
Invalid Stack limit enable setting
Lockout
219
Invalid Stack limit response setting
Lockout
220
Unconfigured Delta T limit set point setting
Lockout
221
Unconfigured DHW high limit set point setting
Lockout
222
Unconfigured Outlet high limit set point setting
Lockout
223
Unconfigured Stack limit set point setting
Lockout
224
Invalid DHW demand source setting
Lockout
225
Invalid Flame threshold setting
Lockout
226
Invalid Outlet high limit set point setting
Lockout
227
Invalid DHW high limit set point setting
Lockout
228
Invalid Stack limit set point setting
Lockout
229
Invalid Modulation output setting
Lockout
230
Invalid CH demand source setting
Lockout
231
Invalid Delta T limit delay setting
Lockout
232
Invalid Pressure sensor type setting
Lockout
233
Invalid IAS closed response setting
Lockout
234
Invalid Outlet high limit enable setting
Lockout
235
Invalid Outlet connector type setting
Lockout
236
Invalid Inlet connector type setting
Lockout
237
Invalid DHW connector type setting
Lockout
238
Invalid Stack connector type setting
Lockout
239
Invalid Header connector type setting
Lockout
240
Invalid Outdoor connector type setting
Lockout
241
Exchanger sensor not allowed with stack connector setting
Lockout
242
Invalid DHW auto detect configuration
Lockout
243
Invalid UV with spark interference not compatible with Igniter on throughout
PFEP
Lockout
244
Internal fault: Safety relay test invalid state
Lockout
245
Invalid Outlet connector type setting for T-rise
Lockout
246
4-20mA cannot be used for both modulation and setpoint control
Lockout
247
Invalid ILK bounce detection enable
Lockout
248
Invalid forced recycle interval
Lockout
249
STAT cannot be demand source when Remote Stat is enabled
Lockout
250
Invalid Fan speed error response
Lockout
251
Lead drop-stage on error setting does not match drop method configuration
Lockout
252
Invalid Line frequency setting
Lockout
253
Lead Lag modulation sensor not valid with setpoint source
Lockout
254
Lead Lag modulation sensor not valid with local setpoint source
Lockout
255
Lead Lag modulation sensor not valid with local modulation source
Lockout
256
Selected Controller interaction enable setting is not allowed
Lockout
257
Controller interaction enable does not match neighbor stack fault setting
Lockout
258
Controller ID must be non-zero if controller interaction is enabled
Lockout
259
Modulation output must be fan if controller interaction is enabled
Lockout
260
Asymmetrical paired (no flap) is set but flap switch input is energized
Lockout
261
Neighbor burner control blower fault detected
Lockout
262
Blower fault detected during flap test
Lockout
263
Invalid DHW demand temperature setting
Lockout