5. Update rating plate
Gas to LP Conversion Kit, you must
indicate on the boiler that it has been
converted for use with Propane (LP) Gas:
a. Update Rating Plate Decal
– Locate
the rating plate decal on the side of
the appliance. Using a regular ink pen,
check the box next to “Field converted
Press hard enough to permanently
mark the decal. See Figure 9.
FACTORY SET FOR NATURAL GAS
Field converted to Propane Gas
ADJUSTER A L’USINE POUR GAZ NATURAL
Convertie au propane sur place
Date:
Date:
Gas Pressure
[Pression du Gaz]
Maximum Inlet Gas Pressure
[Pression maximale d’entrée du gaz]
Minimum Inlet Gas Pressure
[Pression minimum d’entrée du gaz]
Manifold Pressure
[Pression d’admission]
Natural
[Naturel]
Propane
10.5" wc [2.6 kPa]
3,5" wc [1 kPa]
0" wc [0 kPa]
0" wc [0 kPa]
8" wc [2 kPa]
13" wc [3.2 kPa]
October 22,2018
b.
Conversion Decal
- Fill out the
required information on the
Conversion Decal (included in this
adjacent to the rating plate decal, in
a location where it can be easily seen.
See Figure 10.
Figure 9 - Update the Rating Plate Decal
Figure 10 - Conversion Decal
THIS CONTROL WAS CONVERTED FOR USE WITH PROPANE GAS
This appliance has been converted for use with Propane Gas, in accordance with the
instructions provided with the Natural to Propane Conversion Kit
by ______________________________________ , which accepts responsibility that
the conversion was performed properly.
Reference rating plate for Propane Input and Gas Pressure
420060882600