Replacement Instructions  

 

84318 

│ Gas Valve GB-ND 057 

    

Revision Date: 2016/02/16 

S:\NTI2001_N_Drive (1-20-09)\R&D\PARTS - ENGINEERING\Parts Department Stickers and Instructions\Current Parts Instructions (doc)\84318 Gas 
Valve Replacement Instructions Lx 500.docx 

 

NY Thermal Inc.     

Tel: (506) 657-6000     
Toll Free: 1-800-688-2575     
Fax: 1-506-432-1135 
Web: www.nythermal.com 
Email: [email protected]

 

 

84318 

Gas Valve GB-ND 057-DO 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

Replacement Instructions: 

  Shut off the gas and power to the boiler.  

  Remove display and display housing as an assembly (Fig. 1-2 and 1-3).  Remove the boiler jacket top 

(front and rear) and right side. Loosen the left side panel. 

  Remove the gas valve harness and the vinyl hose from the gas valve. 

  Remove the screws securing the gas line adapter to the gas valve inside boiler (Refer to Fig. 1-5). 

  Remove the screws securing the gas valve to the bracket on the left side of boiler (Refer to Fig. 1-4) and 

remove gas valve. 

  Lift the gas valve up from between the gas valve adaptor and the bracket. 

  Reinstall the new valve in the reverse order it was removed and perform a combustion test. Refer to Gas 

      Valve and Burner Setup section in the boiler installation and operation manual included with the boiler. 

 

Fig. 1-2 Display and display housing assembly.  

Fig. 1-3 Display housing 
 

 

 
 
 

Applicable Boiler Models: 

    Lx 500 

 Kit Contains: 

  Valve GB-ND 057 

 

Tools Required: 

  Pipe Wrench (for gas line) 

  Adjustable Wrench (for gas line union) 

 

1/4” and 5/16” Nut Driver 

  Phillips #2 and #1 Screwdriver 

  Torx T20 Screwdriver 

  Torx T25 Screwdriver 

  Needle Nose Pliers (for gas valve vent adapter) 

  Combustion Analyzer 

   Fig. 1-1 Gas Valve GB-ND 057 