background image

 

TROUBLE-SHOOTING

 

PROBLEM 

CAUSE 

SOLUTION

 

 

No solution flow. 

Clogged filter. 

Clean filter. 

 

Low battery charge. 

Charge the batteries. 

 

The solution valve is closed. 

Open the solution valve. 

 

 

Obstruction in the solution hose. 

Remove the obstruction. 

 

 

Solution valve or linkage damaged. 

Repair/replace the valve linkage. 

 

 

Solution hose kinked. 

Check for kinks at valve and remove. 

 

Solution tank is empty. 

Fill the tank. 

 

 

Solution flow does 

The solution valve is open. 

Close the solution valve. 

 

not stop. 

Solution valve or linkage damage. 

Repair/replace the valve linkage. 

 

 

Solution valve is dirty. 

Clean the solution valve. 

 

 

Damaged seat and washer in valve. 

Replace valve. 

 

 

The valve stem is dirty. 

Clean and lubricate valve stem. 

 

 

Hose disconnected or damaged 

Reinstall or replace hose. 

 

between sol. tank & valve. 

 
Will not pick up any 

Squeegee is up. 

Lower squeegee. 

water from floor. 

Squeegee hose is off. 

Reinstall hose. 

 

Vac motor switch is off. 

Turn vac motor switch “on”. 

 

 

Recovery tank is full. 

Empty tank. 

 

 

Vacuum shut-off float is stuck. 

Open float valve/remove obstruction. 

 

 

Obstruction/damage in the squeegee, 

Remove obstruction/repair damage. 

 

 

squeegee hose or standpipe. 

 

 

 

Leaking over gasket. 

Remove old gasket/replace. 

 

 

Vac motor is not running. 

Have an authorized serviceman repair. 

 

Recovery drain hose not plugged properly. 

Install drain hose plug properly. 

 

 
Will not pick up all of the 

Debris on squeegee blades. 

Clean squeegee 

water from the floor. 

Squeegee blade is worn/damaged. 

Reverse/replace squeegee blade.   

 

Obstruction/damage in the squeegee, 

Remove obstruction/repair damage. 

 

 

squeegee hose, or standpipe. 

 

 

 

Squeegee angle needs adjustment. 

Adjust angle. 

 

Vacuum motor worn out. 

Repair/replace vac motor. 

 

Recovery tank drain hose damaged. 

Repair/replace recovery drain hose. 

 

 

Batteries do not seem  

Overcharging batteries. 

Monitor run time and adjust charging  

to run long enough. 

 

frequency accordingly. 

 

Tops of batteries are dirty/wet. 

Clean/dry, charge batteries. 

 

 

Battery terminals are dirty, damaged, 

Clean terminals and connectors,   

 

or loose. 

replace damaged cables. Charge.   

 

Electrolyte level is too low. 

Add distilled water and charge. 

 

 

Batteries are not fully charged. 

Charge batteries for 8 hours. 

 

 

Charger is damaged. 

Have an authorized serviceman repair. 

 

 

Battery is defective or worn out. 

Check cell voltage while discharging. 

 

 
Cleaning is not even. 

Brush/pad is worn. 

Replace brush/pads. 

 

 

Damage to brush assembly, casters 

Have an authorized serviceman repair. 

 

 

or solution valve. 

 

 

 

Machine does not run. 

Circuit breaker tripped. 

Reset circuit breaker.  

 

Loose battery connection. 

Tighten battery connection.

 

 

 

NOTE: If any problems remain after taking the above steps, contact your local authorized 

distributor/service station for further evaluation and repair.

Summary of Contents for WRANGLER 1708CB

Page 1: ...motor or battery charging plug to get wet or a short may occur NEVER operate this machine when the battery charger is plugged in NEVER operate this machine with the side skirt removed NEVER allow this...

Page 2: ...t with battery acid NEVER lay anything on top of batteries as arcing may occur IF CONTACT WITH BATTERY ACID OCCURS follow these instructions SKIN rinse area with water EYES Flush with water for 15 min...

Page 3: ...30 seconds to working level Needle on machine battery gauge should not move when machine is plugged into charger batteries will not be charged NSS supplied battery chargers are automatic and will shu...

Page 4: ...nk Raise the brush motor into the up position The foot pedal is at the rear left of the machine Step on the pedal and slide it to the right into the notch Step on the foot pedal latch at the front of...

Page 5: ...liters warm water Inspect squeegee hose for clogs and holes Be sure red access cap inside tank is in position Monthly Maintenance Verify all daily and weekly maintenance has been performed Lubricate t...

Page 6: ...ecovery drain hose not plugged properly Install drain hose plug properly Will not pick up all of the Debris on squeegee blades Clean squeegee water from the floor Squeegee blade is worn damaged Revers...

Page 7: ...7 NOTES...

Page 8: ...9 531 2121 FAX 419 531 3761 NSS Enterprises Inc European Distribution Centre Unit II Pinfold Trading Estate 55 Nottingham Road STAPLEFORD NOTTINGHAM NG9 8AD ENGLAND U K PHONE 44 0115 939 1568 FAX 44 0...

Reviews: