NSS Opti-Mist P Operation Manual Download Page 5

 

 

 
 

TROUBLE SHOOTING

 

PROBLEM  CAUSE 

SOLUTION 

Shut-off 
leaks. 

The connection(s) is loose. 

Tighten (all) connections. 

Shut-off is worn or damaged. 

Repair or replace the shut-off valve. 

 

 

Wand 
assembly 
leaks. 

Connection(s) is loose. 

Tighten connection(s). 

O-ring and/or gasket is worn or damaged. 

Replace the O-ring and/or gasket. 

 

 

Nozzle 
assembly 
leaks. 

Connection(s) is loose. 

Tighten connection(s). 

O-ring and/or gasket is worn or damaged. 

Replace the O-ring and/or gasket. 

 

 

Leak 
between the 
pump 
assembly 
and the 
solution 
tank. 

Pump is loose 

Tighten the pump. 

O-ring is worn or damaged. 

Replace the pressure chamber O-ring. 

 

 

 

Hose is 
leaking at 
the solution 
tank outlet. 

Hose clamp is loose. 

Tighten the hose clamp. 

 

 

 

Hose is 
leaking at 
the shut-off. 

Connection is loose. 

Tighten the retaining nut. 

O-ring and/or gasket is worn or damaged. 

Replace the O-ring and/or gasket. 

 
NOTE: If any problems remain after taking the above steps, contact your local authorized distributor / service station for further 
evaluation and repair. 

Summary of Contents for Opti-Mist P

Page 1: ...OPERATION MANUAL Opti Mist P Chemical Sprayer ...

Page 2: ... ALWAYS empty the tank after use NEVER allow this machine to freeze NEVER expose the machine to rain snow or extreme temperatures NEVER leave a pressurized machine in the hot sun Heat can cause a pressure build up resulting in possible explosion NEVER store any items on this machine ALWAYS store this machine indoors in a dry cool area NSS Chemical Use Disclaimer WARNING Chemical use hazard Each ch...

Page 3: ...nt clogging while spraying Pressure Relief Valve Pull the valve out to release the pressure stored in the solution tank Carrying Handle There is a carrying handle shipped loose with this machine Install the carrying handle onto the solution tank Spraying Wand Assembly The spraying wand assembly includes a shut off valve and hose wand assembly and spray nozzle Shut off Valve Spray Nozzle Wand Assem...

Page 4: ...spect all connections Tighten as required Weekly Maintenance 20 hours Verify all daily maintenance has been performed Inspect the hose for cracks softness or brittleness Replace if any is found Inspect solution tank for any signs of cracks or deterioration A machine with signs of cracks or deterioration should not be used as it could burst under pressure NEVER attempt to patch any leaks Test shut ...

Page 5: ...sket is worn or damaged Replace the O ring and or gasket Leak between the pump assembly and the solution tank Pump is loose Tighten the pump O ring is worn or damaged Replace the pressure chamber O ring Hose is leaking at the solution tank outlet Hose clamp is loose Tighten the hose clamp Hose is leaking at the shut off Connection is loose Tighten the retaining nut O ring and or gasket is worn or ...

Page 6: ...ir Parts Kit Shut off 4994241 Wand Assembly Replacement 4994251 Repair Parts Kit O rings ALWAYS USE GENUINE NSS REPLACEMENT PARTS OPTI MIST P Rev Orig 07 20 Rev A 07 20 9094942 NSS Enterprises Inc 3115 Frenchmens Road Toledo Ohio 43607 PHONE 419 531 2121 FAX 419 531 3761 mailus nss com www nss com 4994231 4994251 ...

Reviews: