background image

 WARNING

CAUTION

 • This product is not built as waterproof. Do not spill water or a 

chemical solution onto or into the unit. Failure to do so may 
result in fire or electric shock due to a short-circuit or rusting.

 • If you should notice battery fluid leak within the unit, 

deformation of the unit casing or partial discoloring, 
immediately stop use and contact your dealer.

 • Should the leaking battery fluid get into your eyes, 

immediately wash eyes thoroughly with clean water and see 
your doctor. Failure to do so may result in loss of sight.

 • Should the battery fluid leak and adhere to skin or clothing, 

immediately wash the exposed skin thoroughly with clean 
water and completely wash away the fluid. Failure to do so 
may result in skin complications.

 • If you will not use the product for a long period of time, 

remove the batteries from the unit to avoid fluid leak.

 • Exercise sufficient care in using the product by giving 

patient safety first priority.

 • The product is to be used only for dental treatment by 

qualified personnel.

 • Buy commercially available batteries designated in this 

Manual. Thoroughly read each battery manufacturer’s 
manual before using the respective batteries.

 • Do not use or leave the product in a high-temperature 

environment such as under strong direct sunlight, in a car 
under a blazing sun, by a fire, or near a stove.

 • Make sure if the product works properly by using "Tester" 

attached, prior to use.

 • Do not allow any impact on the unit. Do not drop the unit.
 • Pay attention to the direction of batteries when setting. 

Forcible setting in the wrong direction may cause damage 
and fluid leakage due to a short circuit.

3

4

NOTICE  

 • Do not allow conductive materials such as wires, safety 

pins, etc., to enter into the battery case.

 • If chemical, solvent or antiseptic solution is deposited on this 

product, immediately wipe it away.  Discoloration or 
deformation may occur if left as it is.

 • The system functions normally in the environment where the 

temperature is at 0-40

°

C, humidity at 10-85% RH, 

atmospheric pressure at 500-1060hPa, and no moisture 
condensation in the Control Unit. Use at outside of these 
limits may cause malfunction.

 • The unit consumes electricity very slightly even when the 

power supply is off. If you will not use the product for a long 
period of time, remove the batteries from the unit.

 • If the battery mark flashes, replace with a new battery as 

soon as possible. If consumed batteries are kept in this 
product as they are, fluid leakage may occur. In particular, 
pay attention to the manganese dry batteries from which 
fluid is easily leaked due to its structure as it gets older.

 • This product has been designed on the assumption that 

manganese dry batteries or alkali dry batteries are used. 
Charging type batteries such as nickel-cadmium batteries 
and nickel metal hydride batteries of the same shape can 
also be used, however, are limited by the following.

This product does not have charging function.

Even if nickel-cadmium batteries and nickel metal hydride 

batteries are fully charged, they have lower voltage than 
manganese batteries or alkali dry batteries, therefore, the 
battery remaining mark indicates slightly less. This is due 
to a difference in battery voltage, and not a failure.

Summary of Contents for iPex

Page 1: ...Digital Apex Locator iPex OPERATION MANUAL 0197 OM E0285E 001...

Page 2: ...egree of protection against electric shock Type B applied part Method of sterilization or disinfection recommended by the manufacture See 7 2 Sterilization Degree of protection against ingress of wate...

Page 3: ...th or serious injury may occur A hazard that could result in bodily injury or damage to the device if the safety instructions are not followed A hazard that could result in light or moderate bodily in...

Page 4: ...f batteries when setting Forcible setting in the wrong direction may cause damage and fluid leakage due to a short circuit 3 4 NOTICE Do not allow conductive materials such as wires safety pins etc to...

Page 5: ...AAA batteries 1 2V the charging type batteries nickel cadmium batteries nickel metal hydride batteries can be also used 1 Features The attached batteries are free samples Please understand that these...

Page 6: ...lue Bar LCD Displays the target value while flashing Number Display LCD Displays the present position of the top of the file by number Dental Mark LCD This is displayed while the present position of t...

Page 7: ...indicates battery voltage In the case of charging type batteries such as nickel cadmium batteries and nickel metal hydride batteries they have lower voltage than manganese dry batteries and alkali dr...

Page 8: ...on Use this for extension between the file clip or lip hook and probe if necessary Fig 8 Fig 8 Fig 9 Fig 10 Extension Cord 5 Operating Procedures 1 Inspection before use Be sure to carry out an operat...

Page 9: ...robes etc Fig 13 r Check that the number display on the liquid crystal display reaches within 0 2 to 0 9 t Remove the tester when measurement has ended Fig 11 Prevent the tester and file clip from bei...

Page 10: ...a clean cloth in water and squeeze cloth tightly to drain water Use the cloth to wipe away dirt After that wipe off with an alcohol soaked clean cloth 2 Sterilization Autoclave sterilization is recomm...

Page 11: ...to short circuiting of batteries and moisture infiltrating this product Caution on Changing Batteries If the sterilizer has a dry process that exceeds 135 C skip the process Since the bottom shelf of...

Page 12: ...s Contact your dealer Replace with new batteries Connect the probe Connect probe file clip and extension cord No batteries are inserted Are batteries inserted according to the polarity indication posi...

Page 13: ...ontact the dealer Connect the probe file clip and extension cord Disconnect all of the respective cords and directly insert the electrodes on the tester into the probe connector If the number display...

Page 14: ...08 11 01 M...

Reviews: