NSFOCUS ADS M Installation Guide
Copyright © NSFOCUS
12
V4.5R90F02 (2020-02-28)
the anode of the power supply; the jack marked "-" is connected to the cathode of the power
supply; the jack marked "
" is connected to the PGND cable.
Figure 3-3
DC power supply plug of ADS M
Step 4
Insert the DC power plug into the DC socket at the rear panel of the DC power supply, and
fasten the two screws on both ends of the plug with a screw driver to tighten the power cables.
Step 5
For the dual power supply, repeat Step 3 and Step 4 to connect the other power cable.
----End
3.3
Connecting to the Network
Please connect the ADS M to the network according to the actual network structure.
Pay attention to the following during the connection:
Use straight-through cables to connect the switch to the communication interface of the
device.
ADS M can be deployed anywhere in the network. However, to achieve the optimal
performance, you are recommended to connect it to the switch in the backbone network
of the company.
After deployment, please modify network settings immediately to ensure smooth
network connections. For details on default parameters of ADS M, see appendix
You can modify network settings at the following interfaces:
Console management interface.
Web management interface. For details, see chapter