NSFOCUS ADS M Installation Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Version: V4.5R90F02 (2020-02-28) 

NSFOCUS ADS M

 

Installation Guide

 

© 2020 NSFOCUS 

Summary of Contents for ADS M

Page 1: ...Version V4 5R90F02 2020 02 28 NSFOCUS ADS M Installation Guide 2020 NSFOCUS...

Page 2: ...t for the content of this document including but not limited to the layout figures photos methods and procedures which are protected under the intellectual property and copyright laws No part of this...

Page 3: ...ied with the Device 8 2 2 User Provided Tools 9 2 3 Others 9 3 Installation 10 3 1 Installation Procedure 10 3 2 Connecting to the Power Supply 10 3 2 1 AC Power Supply 11 3 2 2 DC Power Supply 11 3 3...

Page 4: ...Installation Guide Copyright NSFOCUS ii V4 5R90F02 2020 02 28 A 2 Default Account of the Web Administrator 21 A 3 Default Account of the Console Administrator 21 A 4 Communication Parameters of the Co...

Page 5: ...4 Rear panel of ADS M NX3 HD2700 5 Figure 3 1 Installation flowchart 10 Figure 3 2 DC power supply module of ADS M 11 Figure 3 3 DC power supply plug of ADS M 12 Figure 3 4 Installing rack mount ears...

Page 6: ...OCUS ADS M Installation Guide Copyright NSFOCUS iv V4 5R90F02 2020 02 28 Tables Table 1 1 Hardware specifications of ADS NX3 M1600E 6 Table 1 2 Power LED 6 Table 1 3 Status LED 7 Table 1 4 Link Act LE...

Page 7: ...he following users Users who wish to know main features and usage of this product System administrator Network administrator This document assumes that you have knowledge in the following areas Networ...

Page 8: ...n which you might perform an action that could result in equipment damage or loss of data Indicates a situation in which you might perform an action that could result in bodily injury A B Indicates se...

Page 9: ...xpanded to support the 10G capability That is to say ADS NX3 M1600E can be expanded to become a high end product 1 2 Product Appearance Real products of different lots or models may differ slightly Im...

Page 10: ...ctor Heat dissipation holes Power switch Power supply 1 Power supply 2 Mute button The device supports two power supplies If only one power supply is configured a sound alert will be generated To clea...

Page 11: ...ght NSFOCUS 5 V4 5R90F02 2020 02 28 HDD caddy Rear Panel Figure 1 4 Rear panel ofADS M NX3 HD2700 Ground connector Fan Power switch Power port Power reset button 1 3 Basic Information Table 1 1 descri...

Page 12: ...32 mm Depth 575 mm Rack 2U rack mount model Power Supply AC input 100 V AC 240 V AC Maximum power 350 W MTBF 60 000 hours Operating Temperature 0 C to 45 C Storage Temperature 20 C to 65 C 1 4 LEDs Th...

Page 13: ...e system is reading and writing data Off The system is idle Link Act LED Table 1 4 describes the Link Act LED Table 1 4 Link Act LED LED Status Description Link On A link has been established Link LED...

Page 14: ...or two power cables for each device Rubber pad Cut into four pieces along the dotted line and attached to four angles or tabs of the device chassis to avoid abrasion Rack mount ears Used to fasten the...

Page 15: ...ed Tools Screwdrivers and screws of various specifications Devices and meters such as terminal and multi meter Antistatic wrist strap 2 3 Others Environment Well ventilated and excellent heat eliminat...

Page 16: ...NSFOCUS ADS M Installation Guide Copyright NSFOCUS 10 V4 5R90F02 2020 02 28 3 Installation 3 1 Installation Procedure Figure 3 1 Installation flowchart 3 2 Connecting to the Power Supply...

Page 17: ...ar panel Step 3 Connect the other end of the power cable to AC power supply socket End 3 2 2 DC Power Supply For the DC power supply the 48V input voltage is appropriate to ADS M Before the power conn...

Page 18: ...g to the Network Please connect the ADS M to the network according to the actual network structure Pay attention to the following during the connection Use straight through cables to connect the switc...

Page 19: ...4 Rack mounting For the rack mounting you need to first install rack mount ears as shown in Figure 3 4 Then place the device on the rack and fasten it with screws Figure 3 4 Installing rack mount ear...

Page 20: ...or details see section 4 2 Network Configuration on the Console To perform configuration on the web based manager follow these steps Step 1 Use a crossover cable included in the accessory box to conne...

Page 21: ...nsole administrator If the user name and password are correct you can successfully log in to the console End Note that you can only operate on the keyboard on the console Type a sequence number as pro...

Page 22: ...ime and press any key to return to the main menu Step 8 On the main menu type 3 and press Enter to configure the system time and press any key to return to the main menu Step 9 After the configuration...

Page 23: ...f the following letters digits and special characters Figure 4 4 Change Password page Step 5 Set a new password and click Next After the system prompts a message indicating that the password is succes...

Page 24: ...st been upgraded to V4 5R89F03 you need to set the locality system time zone and system time but do not need to change the initial password Figure 4 5 Selecting the UI language Step 6 Select a languag...

Page 25: ...fter the first login If a user stays at pages under Traffic monitoring after a successful login the system will never logs the user out of the web based manager even if the user remains inactive If th...

Page 26: ...NSFOCUS ADS M Installation Guide Copyright NSFOCUS 20 V4 5R90F02 2020 02 28 After the configuration is complete the device is ready for use For detailed usage see the NSFOCUS ADS M User Guide...

Page 27: ...ADS NX3 M1600E and ADS M NX3 HD2700 Management Interface 192 168 1 100 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 A 2 Default Account of the Web Administrator User Name admin Password nsfocus A 3...

Reviews: