APPENDICES 1. VE-2B(G) AND NCV-20 COMPATIBILITY
The NCV-20 has backward compatibility with the VE-2B(G), although its outer dimensions are different due to
its compact size.
Appendix 1-1. VE-2B(G) and NCV-20 Differences
Item Description
VE-2B
(G)
NCV-20
Outside
dimension
More compact
39 x 225 x 110
39 x155 x 93
If the mounting fixture option part
"NCV-K1" is applied, the mounting
hole of VE-2B can be used.
See VE-2B outline Dwg.
Refer to the section
4-1”Dimension of
converter”.
Mounting
DIN rail mountable
Not mountable on DIN
rail
DIN rail mountable
Mass Lighter
weight
Approx. 0.9kg
Approx. 0.4kg
Current
position data
gap
Change the current position data of
NCV-20 to the same value as VE-2B(G)
by using "current position setting function".
Please refer to the section "8-4. Current
position setting" for the setting process
of current position setting.
The origin position of NCV-20 is different from
VE-2B by an individual variability.
There are no differences other than those indicated above.
Appendix 1-2. Replacement Models
The VE-2B (G) models and their corresponding NCV-20 replacement models are shown below.
VE-2B(G) model
NCV-20 model
Description
VE-2B
NCV-20NBNVP
Position data binary output
for single-turn type of ABSOCODER sensor (VRE)
VE-2BG
NCV-20NGNVP
Position data gray binary output
for single-turn type of ABSOCODER sensor (VRE)
Appendix 1-3. Switch Settings when Replacing VE-2B (G) with NCV-20
Specify NCV-20 switch settings to obtain the same functions as the current VE-2B (G) which is being
replaced.
(1) Position data "increase direction" setting
■
:
Check ON/OFF status of this switch
□
: No ON/OFF status check required
VE-2B(G) function setting switch
NCV-20 position data increase
direction setting switch
CW
CCW
30
Summary of Contents for NCV-20NBNVP
Page 2: ......
Page 13: ...4 2 ABSOCODER Sensor Units mm 8...
Page 14: ...Units mm 9...
Page 15: ...Units mm 4 3 Extension Sensor Cable 3P S 0102 L 3P RBT 0102 L Units mm 10...
Page 36: ...2 Set of the function setting switch 31...
Page 39: ......