5 minutes Continuous AC Power......................................100Watts
5. Ventilation openings— The ventilation openings should not be
covered at any time while the inverter is operating.
6. Cooling fan— The high speed cooling fan to protect the
inverter from being overheated.
A fault is referred to as a low/high voltage, over heating, and/or
over loading of the inverter. When the inverter goes into the fault
status, the green LED will vanish and the inverter will
automatically shut down. And it’s recommended that you unplug
all accessories/tools from the inverter, and unplug the inverter
when the green LED vanish. The inverter can be reset by
unplugging it and plugging it in again. This should be done
without any accessory/tool plugged into the inverter.
Maximum Continuous Power.............................................. 80Watts
Surge Capability (Peak Power) .......................................... 200Watts
Battery drain with no AC load ...................0.25A (at a 12V input)
Wave Form............................................................ Modified Sine Wave
Rated Input Voltage
........................................................... 13.8 ±0.2V DC
AC outlet .................................................................................... 115V AC
USB port ................................................................................. 5V 500mA
Fuse .................................................................................................. 8 amp
Dimensions(±5mm) ................... 30mm W 123mm L 72mm H
Weight .......................................................... approximately 0.73 lbs
Note:
Inverter Specifications: