background image

Stepper Motor Driver AD1231

YA7159-1/3

- 14 -

6. Handling precautions

6-1.

This driver is a natural cooling type. Put this product in well-ventilated place as possible and space

more than 10mm out around this driver.

6-2.

Do not use in place with dust, oil mist, corrosive gas, etc. Additionally, remove dust periodically.

6-3.

Do not put this driver in place with excessive vibration and shock directly

6-4.

Make sure to keep the signal line (CN2), the power line (CN1) and the motor line (CN3) away from

one another to prevent noises.

6-5.

If there are noise sources such as relays, high-pressure switching equipments or inverters, these

may cause induced and radiation noises mix in the signal lines or power lines and may cause

malfunctions. Make sure to keep the wires and driver from such noise source as possible.

6-6.

Be careful to touch metal parts. It may result in injury on your finger by an angle of the metal.

6-7.

Do not touch the board of this product while the power is supplied. When you move, wire, maintain

and inspect this product, power it off.

6-8.

Be careful to touch the product while the power is supplied and just after the power turns off. The

product may be hot.

6-9.

Keep this driver out of reach of children.

6-10. Store this driver in place within the predetermined range of temperature and humidity. Do not leave it

in place subject to direct sunlight.

6-11. Plug in the connectors closely. Do not insert and remove connectors with wet hands.

6-12. If smoking, abnormal smell or noise occur, shut down the power immediately.

7. Accessories

Connector for CN1

IL-G-2S-S3C2-SA (Japan Aviation Electronics Industry, Ltd) 1 pc

Connector for CN2

IL-G-10S-S3C2-SA (Japan Aviation Electronics Industry, Ltd) 1 pc

Connector for CN3

IL-G-6S-S3C2-SA (Japan Aviation Electronics Industry, Ltd) 1 pc

Contact for connectors

IL-G-C2-SC-10000 (Japan Aviation Electronics Industry, Ltd) 18 pcs

Applicable wire : AWG22 to28

The above components are attached.

Use the following crimp tool for clamping contact.

CT150-1-ILG (Japan Aviation Electronics Industry, Ltd)

Applicable wire : AWG26 to 28

CT150-1B-ILG (Japan Aviation Electronics Industry, Ltd)

Applicable wire : AWG24 to 26

CT150-1C-ILG (Japan Aviation Electronics Industry, Ltd)

Applicable wire : AWG22 to 24

Summary of Contents for AD1231

Page 1: ...YA7159 1 3 Stepper Motor Driver Nippon Pulse Motor Co Ltd...

Page 2: ...1 3 Warranty scope 1 1 4 1 1 5 1 1 6 1 2 Features 2 3 Specifications 3 4 Connection 7 5 System features 10 5 1 Block diagram 10 5 2 SW1 setting 10 5 3 SW2 setting 12 5 4 SW3 setting 13 5 5 LED display...

Page 3: ...epair NPM will repair the product NPM will not provide on site repair Note 2 The warranty period of the repaired product is not extended beyond the warranty period of the product before the failure It...

Page 4: ...lar coil windings Output current can be set by a rotary switch easily It has auto current down function to prevent heat generation during the motor stopping Excitation method can be selected from 2 ph...

Page 5: ...11mA Operation forward current IF 10 to 20mA Maximum response frequency 160kpps Input voltage 5V duty rate 50 Pins 5 to 8 of CN2 Photocoupler Toshiba TLP281 or equivalent 4 Built in 330 ohm resistor F...

Page 6: ...to 80 RH No condensation Storage temperature range 10 to 60 C Others External dimensions 60 W x 50 D x 30 H mm including heatsink Weight 43g including heatsink Cooling system Natural cooling Photocou...

Page 7: ...r the DIR photocoupler is ON or OFF when pulses are input to the CLK terminal Two pulse mode It is a method that the rotation direction CW CCW is decided by whether the pulse is input to the CW termin...

Page 8: ...ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON EORG EORG EORG EORG CLK EORG 5V 4 Components for use Electronic components for use may be changed to equivalents without prior notice In that case constant...

Page 9: ...n is made in the CCW direction DIR signals in the one pulse method CLK DIR Photocoupler ON CCW direction Photocoupler OFF CW direction 4 CCW DIR 5 MTR OFF Motor excitation ON OFF signals Photocoupler...

Page 10: ...example of CN2 Input output interface OFF ON User controller AD1231 When photocoupler is ON the LED lights Input signal Forward current IF 330 5V 330 5V GND Pin 9 of CN2 Pin 10 of CN2 Pins 2 4 6 and 8...

Page 11: ...PWR PWR CW CLK CCW DIR MTR OFF ACD OFF EORG COM1 COM2 A A B B SW1 CN1 CN2 CN3 AD1231 driver DC 24V Power Switch between two pulse and one pulse method Change motor excitation method Switch driving cu...

Page 12: ...B CN3 IL G 6P S3T2 SA VM A B A B M COM COM Motor 5 2 SW1 setting SW1 can switch between the two pulse CW CCW mode or the one pulse CLK DIR mode and also change the motor excitation method You can swi...

Page 13: ...phase excitation step angles become the same both when SW1 2 is ON and OFF However by switching SW1 2 the excitation become as follows 2 phase excitation When SW1 2 is ON the excitation is by 70 of t...

Page 14: ...en TP1 and TP10 GND Please be careful so that probes may not touch other surrounding checkpin terminals It may cause short out We recommend that you clip probes on the terminals with power off and tha...

Page 15: ...W3 with auto current down 5 5 LED display The LEDs D3 and D4 lights under the following conditions D3 It lights green using 5V power supply generated by the DC DC when the control power is ON D4 It li...

Page 16: ...ect this product power it off 6 8 Be careful to touch the product while the power is supplied and just after the power turns off The product may be hot 6 9 Keep this driver out of reach of children 6...

Page 17: ...Stepper Motor Driver AD1231 YA7159 1 3 15 8 External dimensions 8 1 External dimensions including the heatsink Dimension tolerance 0 1 Unit mm Thickness of heatsink 1 5mm 8 2 Board layout...

Page 18: ...anual may be changed without prior notice to improve performance or quality Nippon Pulse Motor Co Ltd Head Office No 16 13 2 chome Hongo Bunkyo ku Tokyo 113 0033 Japan TEL 81 3 3813 8841 FAX 81 3 3813...

Reviews: