NPCatb M 02-01 Operating Manual Download Page 11

11 

5.3 Error alarm 
When a malfunction appears on the screen in the process of operation, instead of the 

concentration  of  the  measured  component,  the  symbol  "E"  (ERROR)  "E1"..."E9"  appears 
on  the  screen  than  activated  a  continuous  light  and  sound  alarm,  which  lasts  about  5 
seconds. 

In this  case, it is necessary  to turn off the  gas  analyzer  and  transfer to the technical 

support service. 

Do not use faulty gas analyzer. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5.4 Battery discharge alarm 
When  the  battery  of  the  power  supply  discharged  below  the  permissible  level, 

warning  signals  about  the  discharge  in  the  form  of  a  light  and  sound  signal  (continuous 
sound for (5 – 6) seconds with the illumination of the display screen) and a flashing contour 
of the battery icon on the display screen. 

After  the  warning  signals,  the  gas  analyzer  can  work  for  another  25  minutes  at  a 

positive ambient temperature or 1 minute at an ambient temperature below (– 10 °C), and 
then  automatically  turns  off  with  a  short-term  light  and  sound  signal  at  the  time  of 
shutdown. 

If you try to turn on the detector after it is disconnected due to the battery discharge 

by the button,        there will be an intermittent light signal during the hold button        , but 
the  detector  will  not  turn  on.  If  necessary,  you  can  try  switching  on  again  only  after 
charging the battery for at least 25 minutes. 

5.5 Switching off the gas analyzer in the measurement mode 
5.5.1 Press the button           of the keyboard. 
 

 

  15:24                  08.08.09  
  100.2 k P а                24°С 

      С Н 4          

   

E2.1 

      О 2                                              

20.9 % 

      С О                              

    

0

P P M  

     

Н 2 S              

   

E3 

 

Summary of Contents for M 02-01

Page 1: ...GAS ANALYZER TOXIC AND FUEL GASES 02 01 Operating Manual Short version...

Page 2: ...2 Contents Page 1 Purpose 3 2 Technical specifications 4 3 Operation and description 5 4 Preparation for work 8 5 Operating procedure 10 6 Safety requirements 13...

Page 3: ...n with frequency 5 35 Hz and amplitude not more than 0 35 mm 1 4 Gas analyzers provide continuous measurement and digital indication of the monitored component indication and signaling sound and light...

Page 4: ...f carbon dioxide volume fraction from 0 to 5 range of indications of the volume fraction of carbon dioxide from 0 to 100 range of ambient air temperature readings from 50 to 50 C range of atmospheric...

Page 5: ...episodic measurements is 4000 records At filling of the specified volume new records are brought in a place of the first It is possible to clear format the memory of occasional measurements in the tu...

Page 6: ...enings for supplying the gas mixture to the sensors 6 made in the form of a grate consisting of inclined plates preventing direct moisture penetration onto the sensors A light conducting zone 7 is loc...

Page 7: ...7 Figure 1...

Page 8: ...as analyzer will pass to the testing phase automatic zero or warm up and a view window for M 02 01 with measurement channels CH4 O2 CO H2S will appear on the display The upper part of the window shows...

Page 9: ...05 along the carbon monoxide measurement channel from 0 ppm to 2 ppm through the hydrogen sulfide measurement channel from 0 ppm to 1 ppm and the reading on the channel for measuring the volume fract...

Page 10: ...t sound intermittent signal appears he display illumination turns on and a blinking icon of the reached first or second threshold level appears on the screen in the gas code line respectively for M 02...

Page 11: ...ith the illumination of the display screen and a flashing contour of the battery icon on the display screen After the warning signals the gas analyzer can work for another 25 minutes at a positive amb...

Page 12: ...croll buttons to move the active marker to TURN OFF 5 5 3 Press the enter button of the keyboard In this case the window with the working menu will be replace by the deactivation window 15 24 08 08 09...

Page 13: ...out work with the gas analyzer observe the requirements of the regulatory documents on occupational safety applicable in the industries where this gas analyzer is used 6 2 WARNING During operation pre...

Reviews: