GAS ANALYZER
TOXIC AND FUEL GASES
М 02-01
Operating Manual
(Short version)
Page 1: ...GAS ANALYZER TOXIC AND FUEL GASES 02 01 Operating Manual Short version...
Page 2: ...2 Contents Page 1 Purpose 3 2 Technical specifications 4 3 Operation and description 5 4 Preparation for work 8 5 Operating procedure 10 6 Safety requirements 13...
Page 3: ...n with frequency 5 35 Hz and amplitude not more than 0 35 mm 1 4 Gas analyzers provide continuous measurement and digital indication of the monitored component indication and signaling sound and light...
Page 4: ...f carbon dioxide volume fraction from 0 to 5 range of indications of the volume fraction of carbon dioxide from 0 to 100 range of ambient air temperature readings from 50 to 50 C range of atmospheric...
Page 5: ...episodic measurements is 4000 records At filling of the specified volume new records are brought in a place of the first It is possible to clear format the memory of occasional measurements in the tu...
Page 6: ...enings for supplying the gas mixture to the sensors 6 made in the form of a grate consisting of inclined plates preventing direct moisture penetration onto the sensors A light conducting zone 7 is loc...
Page 7: ...7 Figure 1...
Page 8: ...as analyzer will pass to the testing phase automatic zero or warm up and a view window for M 02 01 with measurement channels CH4 O2 CO H2S will appear on the display The upper part of the window shows...
Page 9: ...05 along the carbon monoxide measurement channel from 0 ppm to 2 ppm through the hydrogen sulfide measurement channel from 0 ppm to 1 ppm and the reading on the channel for measuring the volume fract...
Page 10: ...t sound intermittent signal appears he display illumination turns on and a blinking icon of the reached first or second threshold level appears on the screen in the gas code line respectively for M 02...
Page 11: ...ith the illumination of the display screen and a flashing contour of the battery icon on the display screen After the warning signals the gas analyzer can work for another 25 minutes at a positive amb...
Page 12: ...croll buttons to move the active marker to TURN OFF 5 5 3 Press the enter button of the keyboard In this case the window with the working menu will be replace by the deactivation window 15 24 08 08 09...
Page 13: ...out work with the gas analyzer observe the requirements of the regulatory documents on occupational safety applicable in the industries where this gas analyzer is used 6 2 WARNING During operation pre...