Calibration and Setup
After entering into calibration and
setup
function, the
tester
shall display
as
shown
.
----SETUP----
=2UNIT METER
CAL
BRAT
|
ON
BUIT
A
quick way to
enter
into dynamic calibration
is
to hold the
“[PAIR&L]”
key while starting the
tester.
For an
accurate measurement
of
cable
length, the calibration
operation should be completed
as
follows:
CALIBRATION?
NO
YES
After entering into the dynamic calibration function, the display
will
be shown on the
tester.
Insert the
same
type
of
cable
of a
given length into port
“M”.
You
do not need to
connect
the receiver.
Your excellent helper in cable test!
Press
the
[Alkey
(yes) to
undertake measurement
and display
the
measured
length
.
PIERSE
HBJUST?
20.0M
-
OK
+
Press
and hold the
[Al
and
[Wl
key (-/+) to display the length to be
adjusted
to
the actual given length and then
press
the“
[PAIR3L]”
key to
reserve
calibration factor and exit calibration function.
If
the cable length being
measured
is
too short (<10m) the
display
will
remind you to
change
to
a
longer
cable
for
calibration.
Press
the
[W]
key (no) to exit the calibration function.
Press
the
[al
key (yes) to
repeat
the
measurement.
Note:
If
the
tester
is
restarted after
it
turns
off,
it
will
recover
the
standard
calibration factor
of
class
UTP5
cable as set
up
in
manufacturing.
Your excellent helper in
cabile
test!