background image

Your excellent helper in cable test!

6

7.6 Interpreting the Results:
7.6.1  Power LED:

The Power LED should light whenever the “Test” Button is 
pressed and released. It will be on for a minimum of 5seconds. 
If the power LED does not light, replace the battery.

7.6.2 Low Battery LED:

The low Battery LED  should not light . If it does, replace
the battery.

Your

 

excellent

 

helper !

7.6.3 No connection LED/Single Beep

If the Remote is not connected to the Main unit with a cable, 
or the cable has no intact conductors, the No Connection 
LED will light and the Beeper will sound Once. 

Note:

When testing an RJ-45 UTP cable. The S/G LED must not light.
When testing an RJ-45 UTP cable. The S/G must light.

The 4 in 1 is intended to test complete cables. It may not find 
faults in cables that are intentionally incomplete. For example, 
the standard EIA/TIA 568 RJ-45 terminated Ethernet cable is 
expected to contain 8 conductors. If only 4 conductors are 
used between the RJ-45 connectors, the 4 in 1 may not 
properly identify the faults. 

RJ-11 cables may have 2 connections, 4 connections, or as many 
as 6 connections .For 2 connection cables, LED 3 and  4 must 
light . For 4 connection cables, LED 2, 3,4 and 5 must light. For 6 
connection cables, LED 1,2,3,4,5 and 6 must light.

Summary of Contents for NF-3368

Page 1: ...ent cts at P iting not a rfe ll te o n w ou ed C ORIGINAL AUTHENTIC REV1 0 Your excellent helper in cable test MODEL NF 3368 NF 3468 INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTIO...

Page 2: ...o d u c t i o n 1 Safety Rules and Warnings 1 Product Features 2 Speciflcations 3 interfaces 4 Operation 4 Maintenance 8 Accessories 8 Diagram of series products 9 Your excellent helper in cable test...

Page 3: ...ded for live circuits Attaching this tester to a powered circuit will result in damage to the tester or injury to the user 2 1 Read all instructions in this manual before using this tester Failure may...

Page 4: ...n the tester isn t used for more than 1 month Chemical leakage from the battery could damage the tester 3 PRODUCT FEATURES 3 1 Test 4 types of cables 3 2 Simple one button test 3 3 Ergonomic portable...

Page 5: ...A TIA 568 RJ 11 cables with male connectors 2 to 6 conductors installed USB cables with Type A flat plug on one end and type B square Plug on other end BNC cables with male connectors 4 2 Faults Indic...

Page 6: ...rmation The 4 in 1 Cable Tester NF 3468 it functions by pressing one single button on the panel User can get clear test results from the 8 light and knowing the cable is connected No connection shor o...

Page 7: ...e other into the remote unit It is unecessary to remove the remote unit from its docked position on the Main unit 7 4 Testing Installed cables If the two ends of testing cable are not in the same loca...

Page 8: ...ED will light and the Beeper will sound Once Note When testing an RJ 45 UTP cable The S G LED must not light When testing an RJ 45 UTP cable The S G must light The 4 in 1 is intended to test complete...

Page 9: ...her connections in the cable are not indicated If more than 3 numbered LEDs light there may be multiple shorts in the cable 7 6 5 Connected LED 2Beepers Cross LED Numbered LEDs If the Connected LED li...

Page 10: ...equired To clean outside of the tester use a cloth dampened with a mild detergent solution Do not use any abrasive cleansers or chemical solvents that may damage the tester 9 ACCESSORIES 9 1 The 4 in...

Reviews: