Novy 7550 Operating And Installation Instructions Download Page 4

EN 17

Technical information:
- Power supply: (2xAAA) batteries
- Frequence: 433.92Mhz
- Numbre of codes: 10
- Worktemperature: 0-50°C
- Dimensions: 110 x 50 x 19mm

3.4 InTouch

The cooker hood features the InTouch function. If you 
have a Novy induction plate with InTouch, you can ope-
rate the hood from the plate. Programming InTouch on 
the induction plate.

Programming InTouch on the induction plate 

The remote control must first work with the hood. If ne-
cessary, the remote control code can be changed, as 
described in Section 3.3.

Connect the plate to the mains supply.

1. Touch simultaneously the keys 

 and   on the in-

duction plate until you hear a beep signal.

•  The hob will now search for the hood code auto-

matically.

•  WAIT until the hood lights flash, OR until you hear 

a clicking sound eight times from the hood. (Be 
patient, this may take a while)

2.  Then touch any InTouch key, 

  or    or   or   on 

the induction plate until you hear a beep signal. This 
is the confirmation of the pairing of both devices.

Now you can operate the hood with the keys on the 
induction plate.

4. MAINTENANCE

4.1. Grease filter

Maintenance of the grease filter
The cooker hood contains 4 metal grease filters. The 
cooker hood has a cleaning indicator for the grease 
filters.
Grease filter indication

  Indication: green indicator lamp starts

 

 burning.

After 20 cooking hours, an green lamp on the hood 
indicates that the grease filter needs cleaning

Access to the filter

The two side panels can be opened. 

  Attention: hold the hood with one hand and 

open the side panel with the other hand.

Remove the filter by taking hold of its hook and pulling 
down.

Cleaning the filter:
•  in the dishwasher
•  manually: in a hot solution of water and a liquid de-

tergent. Rinse and allow to dry completely

  The previous instructions need to be followed. If 

not an increased fire hazard may occur.

After cleaning, place the grease filters back in the hood. 
Do not use the hood without the grease filters.

Reset grease filter indication
When you replace the monoblock filters after cleaning, 
press the [+] and [-] buttons simultaneously for 5 
seconds to reset the cleaning indicator. If you don’t 
reset, the green indication light will continu burn. We 
advise you to clean your filter once a month for an 
optimal operation.

4.2 Monoblock filters

In each grease filter there are 2 half round black mono-
block filters. Only use the Novy Monoblock recircula-
tion filter in the cooker hood.

Cleaning indication monoblock filter

  Indication: orange indicator lamp starts  

burning

Summary of Contents for 7550

Page 1: ...NL Gebruiksaanwijzing en installatievoorschriften p 2 FR Mode d emploi et d installation p 6 DE Montage und Bedienungsanleitung p 10 EN Operating and installation Instructions p 14 7550 7550_10508_GA1 ...

Page 2: ...from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Activate the hood a few minutes prior to cooking Switch the hood off 30 minutes after cooking is finished The delay function is set to 30 minut...

Page 3: ...tched off the cooking mode the last set value will always be remembered In this way your preference will be used every time when switching on the hood Mood mode The mood mode provides optimum lighting for creating a nice atmosphere This mode has by default a lower light intensity than the cooking mode both at the bottom and along the sides of the hood Press key 5 to switch the mood mode on or off ...

Page 4: ...etal grease filters The cooker hood has a cleaning indicator for the grease filters Grease filter indication Indication green indicator lamp starts burning After 20 cooking hours an green lamp on the hood indicates that the grease filter needs cleaning Access to the filter The two side panels can be opened Attention hold the hood with one hand and open the side panel with the other hand Remove the...

Page 5: ...ack into place above the monoblock filters with the grip turned inward Reset the Monoblock recirculation indication When you replace the monoblock filters after cleaning press the and buttons simultaneously for 5 seconds to reset the cleaning indicator If you do not do this the orange light will continue to shine when you turn on the extraction hood 4 3 Maintenance of of the cookerhood Use a soft ...

Page 6: ...AFMETINGEN DIMENSIONS ABMESSUNGEN DIMENSIONS 19 ...

Page 7: ...20 ELEKTRISCH SCHEMA SCHÉMA ÉLECTRIQUE ELEKTRISCHER SCHALTPLAN ELECTRICAL SCHEME ...

Page 8: ... et les prix de ses produits Die NOVY AG behält sich das Recht vor zu jeder Zeit und ohne Vorbehalt die Konstruktion und die Preise ihrer Produkte zu ändern NOVY nv Noordlaan 6 B 8520 KUURNE Tel 056 36 51 00 Fax 056 35 32 51 E mail novy novy be http www novy be France Tél 0320 940662 Deutschland und Österreich Tel 49 0 511 54 20 771 Nederland Tel 31 0 88 0119110 España Tel 34 938 700 895 Italia Te...

Page 9: ...areil correspond aux exigences techniques locales type de gaz tension fréquence conditions d installation conditions climatiques Les dégâts occasionnés par une utilisation non conforme ou adéquate et les adaptations nécessaires ou souhaités ne sont pas concernés par les conditions de la garantie Demande de réparation En cas de pièce défectueuse il convient de vous adresser à votre revendeur ou ins...

Page 10: ...n België Les conditions de garantie en Belgique Die Garantiebedingungen in Belgien p 2 4 Les conditions de garantie en France p 5 Für Garantiebedingungen in Deutschland For all other countries Naam Nom Name Name Adres Adresse Adresse Adress Faktuurdatum Date de facturation Datum der Rechnung Invoice Date Zie achterkant Voir au dos Sehen Sie die RuckSeite See back ...