NVIP-TDN3401H/IR/MPX2.0
User’s manual ver.1.0
All rights reserved © AAT Holding sp. z o.o.
33
ELECTRIC CONNECTORS AND ACCESORIES
5. ELECTRIC CONNECTORS AND ACCESORIES
5.1. Description of camera connectors.
NVIP-TDN3401H/IR/MPX2.0
Description of alarm input/output connector terminal is presented in the table below:
Input and output connector states:
Input 1
Normal state
3,3V
-
Active state
0V
I<1mA
Relay output
Normal state
Connected N.C. - COM
Active state
Connected N.O. - COM
1A, 24VDC,
0.5A, 125VAC
1-Relay output connector N.O.
2-Relay output connector common
3-Relay output connector N.C.
4-Input ground - GND
5-Input 1