Network connection using external power supply, directly to the computer.
1.3. Initial configuration via the web browser
The default network settings for IP PTZ cameras 5000 series are :
1. IP address =
192.168.1.200
2. Network mask -
255.255.255.0
3. Gateway -
192.168.1.1
4. User name -
root
5. Password -
pass
Knowing the camera’s IP address you need to set PC IP address appropriately, so the two devices can
operate in one network subnet (e.g. for IP 192.168.1.1, appropriate address for the camera is from range
192.168.1.2 to 192.168.1.254, for example 192.168.1.60). It is not allowed to set the same addresses for
camera and PC computer
You can either set a network configuration (IP address, gateway, net mask, etc.) of NOVUS IP camera
yourself or select DHCP mode (DHCP server is required in this method in target network) by using
web browser or by NMS software. When you use DHCP server check IP address lease and its linking
with camera MAC address to avoid changing or losing IP address during device operation or network/
DHCP server breakdown. You have to remember to use a new camera IP address after changing
network parameters.
After network setting configuration has been done, the camera can be connected to a target network.
START-UP AND INITIAL CAMERA CONFIGURATION
IP Camera
Network transmission - cross over cable
Computer