NVIP
-
8VE
-
6202M
-
User
’
s manual (short form) ver 1.0
NVIP
-
5V
-
6202M
Quick start guide
version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
19
6.3. Hardware factory settings restoring
In order to restore factory settings using reset button
(RST),
please follow the instructions below:
•
Unscrew the camera cover
(3)
by turning counter
-
clockwise.
•
Remove the camera housing
(2).
•
Press the reset button
(2)
and hold on for 10 seconds.
•
Release button.
•
Screw the camera housing
(2)
back on camera
•
Screw the camera cover
(3)
by turning it clockwise
•
Log on after 1 minute using default IP address (
http://192.168.1.200
) and default user name (
root
)
and password (
pass
).
FACTORY SETTINGS RESTORING
1
2
3