6. RESTORING FACTORY DEFAULTS
NOVUS IP cameras allow to restore defaults via:
software (web browser level)
hardware (using reset button)
6.1. Restoring factory defaults by software means
User can restore default settings of the IP camera except network settings (optional). To restore to
default settings go to:
Maintenance -> Device Restart
tab. Process of restoring takes about two
minutes.
6.2. Restoring factory defaults by hardware means
In order to restore factory defaults for the camera please follow the instructions:
Unscrew two screws holding camera cover dome using allen key and remove camera cover.
Press the
RESET
button and hold on for 5 seconds
Release button
Mount camera cover dome and screw to camera base.
Log on after approx. 2 minutes using default IP address (http://192.168.1.200) and default user
name (root) and password (pass)