NVH-300H /230, NVH-300H/12/24– user’s manual, ver.3.0
All rights reserved © AAT Holding sp. z o.o.
9
MOUNTING
4. Mounting camera in housing
1.
Select suitable mounting location and lead all cables near the bracket.
2.
Mark mounting position and drill 3 holes for plastic anchors.
3.
Screw on bracket to the wall using 4 tapping screws witch plastic anchors.
4.
Unscrew 3 screws connecting parts of the housing with Hex L-wrench.
5.
Open the housing
6.
Feed on the necessary cables through the cable channel and screw on cable clamp
for cable channel sealing.
7.
Screw on housing to the bracket with 4 screws
8.
Connect housing power cables to terminal FTB.1 with proper polarization (refer to
previous page)
9.
Dismount mounting base (unscrew 4 screws)
10. Screw on camera to the mounting base with additional skrew. Remember to use
isolation separator and isolation washer for camera isolation. Refere to Picture
below
The camera mounting place sholud be chosen depending on camera-lens length.
CAUTION: It is not advised to install camera-lens kit directly above heater shield. Heat
emited from the heater may cause grease evaporation from mechanical part of lens. It can
damage lens mechanism.
11. Screw on mounting base with camera to bottom part of the housing. Longitudinal holes
allow to set camera possition according to the heater.
12. Connect power and other necessary signals to the camera. Use TB.1 terminal
connectors.
13. Check and if necessary set lens focal length and sharpness
14. Close the housing.
Camera
Mounting base
Mounting base
Isolation separator
Isolation washer
Camera mounting
screw
Cross-section