USERS MANUAL
NR2110-R/O/G
REVISION
B
DATE
120120
Page #:
21 of 47
www.novuspower.com
Example:
The output of channel 1 is connected to a high impedance input and
reports 1.25Vrms at the output.
Alert threshold is set to +/-20%.
The current state is saved in the save configuration screen.
The Channel 1 alert will report when:
-
The Channel 1 output is higher than 1.50Vrms
-
The Channel 1 output is lower than 1.00Vrms
-
To adjust the alert threshold from the front panel, hold the NEXT and
SELECT buttons down simultaneously for two seconds. The percentage
value will begin flashing. To increase the value, press the SELECT
button. To decrease the value, press the NEXT button.
When the desired value is reached, press the NEXT and SELECT button
simultaneously to leave the settings mode.
The alert threshold settings can be modified via the RS232 serial port with
the $FLTTHR command.
For details on the alert t
hreshold, see Programmer’s Guide.