RECORDER’S MENU
To ensure a proper cooperation with PTZ cameras settings entered here should be in accordance with
ones entered in the PTZ cameras. When the system doesn’t employ PTZ or other cameras equipped
with RS-485 communication interface changing settings in this tab is not advised.
PTZ
tab allows for defining the connection speed, the type of control protocol and the ID number of
particular speed dome camera.
First column allows for enabling / disabling the PTZ camera control possibility.
Model
field allows for selecting the communication protocol from available (
N-Control, Pelco-P i
Pelco-D
) please note that the protocol selected here should be the same as one selected in the camera.
Address
field allows for assigning a unique ID number to the camera in a system (using the same
address as the one set in the camera is strongly advised). Assigning the same number to more than one
camera is not advised.
Speed
column allows for setting the camera control speed.
Note:
Pelco-D (N) protocol is a special modification of Pelco-D protocol that allows control of
selected PTZ and box cameras with RS-485 Novus brand. Using this protocol setting
minimum and maximum speed values in the Speed column is not recommended.
Note:
To enable the possibility of controlling the camera via N-Control protocol value in the
Speed
column should exceed 5.
After selecting the
Covert
tab, the following screen appears:
This tab allows for enabling / disabling as well as programming up to 40 covert camera operation
schedules.
To add a schedule please select
+
button.
Day
column allows for selecting the days that the schedule tasks will be performed. The following
values are available:
SUN
(Sunday),
MON
(Monday),
Tue
(Tuesday),
WED
(Wednesday),
THU
(Thursday),
FRI
(Friday),
SAT
(Saturday),
MON~FRI
,
SPECIAL
(special days, defined beforehand in
the
Date / Time
submenu),
All
,
SAT~SUN
(Saturday-Sunday).
From ~ To
column allows for setting the time interval (in the 15-min. increments) that the schedule
will be executed in.
Mode
column allows for setting the covert mode for the cameras.
Off
- function disabled