Specifications______________________________________________________________________
Model
401/410
501
601/610
Gross Content
litre
400
500
600
Net Content according to EN 23953
litre
320
404
484
Total display area (TDA)
M
2
0.7
0.85
0.92
Classification according to EN 23953
3L1
3L1
3L1
Ambient Temperature Range
O
C
+16 to +25
+16 to +25
+16 to +25
Inner Temperature Range
O
C
-18 to -25
-18 to -25
-18 to -25
Sound pressure at 1M distance
Db (A)
<42.3
<42.3
<42.3
Nominal Voltage / Frequency
V/Hz
220-240
̴
50
220-240
̴
50 220-240
̴
50
Nominal Power cabinet
W
290
290
290
Nominal Power LED
W
14
14
Nominal Current
A
1.3
1.3
Fuse Protection
A
16
16
16
Energy Consumption
kWh/24h
2.5
2.2
2.7
Length of power supply cord
mm
2000
2000
2000
Glass UG Value (EN673)
W/m
2
K
3.2
3.2
3.2
Refrigerant
Type
R290
R290
R290
Gas Charge (R290)
g
80
90
90
Maximum operating pressure
bar
30
30
30
Maximum Heat Output
W/h (Btu/h) 386 (1316)
386 (1316)
383 (1316)
Net Weight (ex packaging, inc accessories)
kg
79
90
103
Gross weight (Inc packaging & accessories)
kg
90
110
120