6.2 ポジションマーカー /Position marker

7 電気接続 /Electrical connention

  

7.1 M16x0.75、 6 ピンフランジコネクタ /6 pin frange Connector

注文コードの例:TH1- _ _ _ _ --_ _ _ --_ _ _ -105/Example ordering code: TH1- _ _ _ _ - _ _ _ - _ _ _ -105

       ピン構成  

 フランジコネクタの正面図

供給電圧 Ub / Supply Ub 

シールド / shield

接続なし / do not connect

  ピン割り当て / Pin assignment  

信号 /  Signal

  M16 コネクタ / M16 connector

  コード

ピン 5 / pin 5

ピン 6 / pin 6

ピン 2 / pin 2

ピン 1 / pin 1

ピン 3 / pin 3

ピン 4 / pin 4

Summary of Contents for TH1 CANopen

Page 1: ...tallation 4 5 Wiring 4 6 Mounting and installation 5 6 1 Screw flange M18x1 5 5 6 1 2 Installation example 6 6 2 Position marker 7 7 Electrical connection 7 7 1 M16x0 75 Code 105 7 7 2 M12x1 Code 106...

Page 2: ...k connections Improper connections and overvoltage can damage the transducer Check the connections always carefully before turning on system Potential differences between supply voltage GND and signal...

Page 3: ...In case of strong HF interference it is necessary to use shielded cables It requires checking depending on the user s grounding concept if only one side or both sides of the shield should be connecte...

Page 4: ...tightening torque must never exceed 50 Nm when fastening down the sensor head The bore in the piston rod has to be laid out dependent on the pressure and the velocity of the movement The recommended b...

Page 5: ...6 Installation 6 1 M18x1 5 Screw flange M18x1 5 TH1 CANopen TH1 CANopen User Manual Z TH1 P18 Z TH1 P19 Z TIM P20 Z TH1 P18 Z TH1 P19 Z TIM P20 51mm 104 108 30mm 102 106 O Page 5...

Page 6: ...ANopen TH1 CANopen User Manual O Z TH1 P18 Z TH1 P19 Z TIM P20 50mm 6 0 2 X X O O Y ISO 6149 O Page 6 Dk 25 25 M18 1 5 M18 1 5 30 51 30 min 22 min 22 min 15 min 5 19 8 0 1 0 1 1 5 R 0 1 0 1 4 5 5 M18...

Page 7: ...7 Electrical connention 7 1 M16x0 75 6 6 pin frange Connector TH1 _ _ _ _ _ _ _ _ _ _ 105 Example ordering code TH1 _ _ _ _ _ _ _ _ _ _ 105 Ub Supply Ub shield do not connect Pin assignment Signal M16...

Page 8: ...assignment Signal M12 M12 connector 5 pin 5 2 pin 2 1 pin 1 3 pin 3 4 pin 4 CANopen EDS Novotechnik The description of CANopen interface and the electronic data sheet EDS can be downloaded from Novote...

Page 9: ...female connector straight M12x1 5 pin for wire gauge 6 8 mm max 0 75 mm EEM 33 73 P N 005645 Mating female connector angled M12x1 5 pin for wire gauge 6 8 mm max 0 75 mm EEM 33 75 P N 005646 Cable se...