![NOVOBOX Novocold 10 Installation And Operation Manual Download Page 20](http://html1.mh-extra.com/html/novobox/novocold-10/novocold-10_installation-and-operation-manual_1712268020.webp)
4
THESE INSTRUCTIONS ARE FOR NOVOCOLD 10,
NOVOCOLD I, NOVOCOLD II JA NOVOCOLD DUO.
IT IS VERY IMPORTANT TO READ THESE INSTALLATION
AND OPERATING INSTRUCTIONS CAREFULLY BEFORE
YOU START USING THE EQUIPMENT FOR THE FIRST TIME.
ALSO, PLEASE KEEP THESE INSTRUCTIONS IN A SAFE
PLACE FOR FUTURE REFERANCE OR USE BY ANOTHER
OPERATOR.
BY FOLLOWING THESE INSTRUCTIONS YOU CAN
IMPROVE THE PRODUCTS PERFORMANCE AND REDUCE
UNNESSARY REPAIR COSTS. PLEASE NOTE IT IS
IMPORTANT TO HAVE YOUR EQUIPMENT REGULARLY
MAINTAINED BY A PROFESSIONAL ENGINEER.
YOU WILL FIND THE TERMS OF GUARANTEE IN PAGE 8.
___________________________________________________
TABLE OF CONTENTS
Receipt
4
Installation
3
Introduction
4
Use
4
Installation of the dosing valve
5
Filling
tank
6
Filling
bag
6
Defrosting
7
Cleaning
7
Function
failures
7
Disposal of the equipment
8
Guarantee
8
Service during the guarantee period
8
RECEIPT
Check the product as soon as you receive it. If you notice that
it has suffered from damages during transportation, you must
indicate this in the delivery documents and tell about the matter
to the carrier off the retailer.
The manufacturer’s guarantee does not cover damages
caused by transportation!
INSTALLATION
Unpack the cabinet as close to the installation place as
possible. Remove the protective fi lms on exterior surfaces of
the cabinet. Ensure the cabinet is horizontal on an even level
surface.
When cabinet is delivered and if temperature is cold,
condensation may form on the exterior surface.
Do not connect power
until unit is dry and at
room temperature!
The ambient temperature
must not 30°C or
fall below +5°C.
Avoid placing the cabinet
in direct sunlight or close
to any equipment radiating
heat, such as cookers and
radiators.
Ensure that the air circulation in and out through the side holes
of the equipment is not blocked.
The unit should be connected to an earthed socket or
isolator with 220/240 V / 50 Hz supply.
INTRODUCTION
Kylning får startas först efter två timmar från installation!
Kylsystemet måste nå rumstemperatur och oljan måste rinna
ner till kompressorns oljeutrymme.
Novocold are designed for selling of pre-cooled beverage, not
for storing.
Clean the cabinet carefully before usage using a mild
detergent. Do not use scouring powder, wire wool or
chlorine, i.e.bleach type cleaners.
Switch on the cold system
using the current switch
behind the dosing valve.
The switch light is lit
when the system is
running.
USE
Let the temperature go down to +5°C before putting the
drink box in the cold cabinet.
The thermostat has been preset to the correct temperature by
the manufacturer. If you have to adjust the thermostat, there is a
hole for it over the type plate behind the equipment.
For adjustment you need a chisel point screwdriver.
Novocold 10, l ja ll
Novocold DUO
When turning the adjusting screw right, clockwise, the cabinet
becomes colder.
When turning the adjusting screw left, anticlockwise, the cabinet
becomes warmer.
Avoid opening the door and keeping it open unnecessarily.
This unit is NOT designed for use out of doors. Neither must it
be exposed to any of the elements (ie rain, frost, snow...).
ENGLISH