Bedienungsanleitung
WACTR
09/2016 | 01
49
SERVICE FUNCTIONS menu
Head dot test
Checks the printhead for faulty dots. The check ends with a status report [32] containing a list of
faulty dots. This printout is generated even if no faulty dots were found.
The following screen appears during the check:
Required label material: 200 x 100 mm (length x width).
[32] Status report after the dot check has been successfully completed. Top section: Technical data for the printhead; bot-
tom section: faulty dots.
The dot check can also be started in offline mode by pressing the APPLY + FEED keys. There
is no status report in this case, however.
Print test
A general print test; prints the set printer type and the number of the firmware version in different
fonts arranged by line with material settings such as material type, length and width also taken into
consideration.
To exit the print test press the ONLINE key.
CAUTION!
Danger of damage to the printhead.
Do not switch off the printer under any circumstances during the dot check! Failure
to observe this instruction may cause dots to be destroyed.
Head dot test
Please wait ...