Service manual
XLP 504 / XLP 506
05/2018 | 04
74
Service Electronics
OUTPUT STAGE BOARD M4A FOR STEPPER MOTOR
Connections, settings
[109] Connections at the output stage board (A2742)
A
Connection for D-Sub-harness, sensor of the peripheral device (cable marking „SENSOR 1“
(J4)
[110] Connection diagram sensor.
B
Jumper J6/J1/J7. Caution! - Fig. [109] doesn´t show the correct jumper setting.
[111] Jumper J6 geschlossen.
C
Connection for D-Sub-harness, motor of the peripheral device (cable marking „MOTOR“ (J3)
[112] Connection diagram motor.
D
Connection CPU board (J2)
E
Connection power supply (J12)
A
C
C
D
E
C
B
A
K (GND)
C
E (GND)
J6
J1
J7
M
A
A\
B
B\
Summary of Contents for XLP 504
Page 1: ...Edition 9 5 2018 Translation of original version SERVICE MANUAL XLP 504 XLP 506 Label printer ...
Page 2: ......
Page 238: ...Service manual XLP 504 XLP 506 05 2018 06 238 Appendix WIRING DIAGRAMS See next pages ...
Page 248: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...