01/13 Rev. 5.05-01
USER / SERVICE MANUAL
Mounting and setting the LTSI
LTSI
Setting the Applicator
10
Adjusting the Applicator Home
Position
After fitting the applicator, the home position of the ap-
plicator must be checked and adjusted if necessary.
When viewed from the side, the applicator plate must
stand slightly above and in front of the dispensing edge
[4].
The following guide values may used for the dis-
tances from the dispensing edge:
• Horizontal: approx. 1 mm
To adjust: Shifting of the left aluminium plate [5A]
– upwards --> shifts the home position further
away from the dispensing edge.
– downwards --> shifts the home position closer
to the dispensing edge.
• Vertical: approx. 0.5 mm
To adjust: Shifting of the right aluminium plate [5B]
– upwards --> shifts the home position upwards.
– downwards --> shifts the home position down-
wards.
[9]
Applicator in home position.
[10] Adjusting the home position. Remove the gaiter to get to tho-
se aluminium plates.
A
B