Operating manual
LTSA LTMA
SETTINGS IN THE PARAMETER MENU
Describes the settings necessary in the parameter menu of the XLP 504/XLP 514 for operation of the
applicator.
Overview of parameter settings XLP 504 with LTSA
As soon as “LTSA” is selected as peripheral device, the submenus
Options
>
Dispenser
and
Options
>
LTSA
with parameters for setting the dispensing and applicator functions are also displayed.
The submenu
Options
>
I/O Board
appears only if the optional I/O board is installed.
Submenu
Parameter
Setting
Mandatory
Options
External signal
Singlestart
X
Options
>
Selection
Periph. device
LTSA
X
Options
>
I/O Board
Start print mode
[2]
“Pulse rising” or “Pulse falling”
X
Start source
Foot switch
X
Dispenseposition
0 mm
Dispense Mode
Real 1:1 mode
X
Options
>
Dispenser
Application mode
Immediate mode
Apply mode
After start sig.
Stroke length
190 mm
Appl. waitpos.
0 mm
Applicator speed
350 mm/s
Options
>
LTSA
Restart delay
0 ms
Table 3: List of the most important parameters for applicator operation. The parameters marked “Mandatory” must be set as
shown in order that the applicator functions. The settings for the other parameters are given as recommendations and can be
changed, depending on the application.
Further parameters for integration of the printer into an application with product conveyor and prod-
uct sensor are available in submenu “Dispenser”. In addition, the optional signal interface (I/O
board) is necessary for automatic applications for the processing of external start signals.
For further information on parameter settings, refer to the Operating manual XLP 50x, chapter “Pa-
rameter menu”.
2
Only with installed I/O board (option). This parameter also influences a connected foot switch.
Edition 02 - 7/2021
22
Commissioning
Settings in the parameter menu