05/16 Rev. 03
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
AP 4.4 – AP 5.4
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
131
Pause input
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
Only with USI board.
Concerns the output signal PAUSE\ of the USI.
Standard
(Default setting) A "low" signal for 20 ms switches the DPM / PEM to the
pause status. The pause status equals the status "on-line stopped" and can
be closed by pressing the feed button.
JP6
A signal different from the standard PAUSE\ can be used. Precondition: an
appropriate firmware change (NISTAN).
Start error stop
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
Only with USI board.
Determines the reaction of the machine on a product start error. A product
start error occurs in the following cases:
•
If a further start signal arrives, before the current label is completely printed.
•
If a reprint is requested, before the first label after powering on is printed.
•
If a start signal arrives and no printjob is loaded.
If a product start error occurs, the machine stops and displays the appropriate
status report. At the same time, the following output signals are activated (set
low):
•
ERROR
•
MACHINE STATUS
On
Start errors are worked up (the machine stops!) (default setting)
Off
Start errors are being ignored.
Internal inputs
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
Only with USI board.
Defines, if the internal inputs (CN300) on the USI board will be used or not.
To find the location of the inputs, refer to the service manual, topic section
"Circuit/Component Diagrams", chapter "USI board".
On
The internal inputs will be enabled.
Off
The internal inputs will be disabled.
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...