06/16 Rev. 04
SERVICE MANUAL
Service Electronics Gen. 3
64-xx Gen. 3 – DPM Gen. 3 – PEM – ALX 92x Gen. 3 – ALX 73x (PMA)
83
Sensors output stage boards (64-xx)
Sensors output stage boards (DPM/PEM/ALX)
Sensor
#
Sensor
name
Description
Typical Value Condition
2.01
Foil
Foil sensor
0
Sensor above a hole in the oscil-
lator disc (light barrier clear)
254
Sensor covered
3.01
Head
Light barrier at the print-
head raising mechanism
0
Printhead in economy position
(raised)
254
Printhead in print position
(lowered)
4.01
Option
Sensor for options (ap-
plication for cutter, exter-
nal rewinder or release
motor sensor at the
64-
xx dispenser
)
>10
Light barrier covered
<10
Light barrier clear
[Tab. 9]
Testbedingungen für Sensoren, die an eine der Endstufen-Platinen angeschlossen werden.
Sensor
ID
Sensor-
Name
Beschreibung
Typische
Werte
Bedingung
2.01
Folie
Foil sensor
0
Sensor above a hole in the oscil-
lator disc (light barrier clear)
254
Sensor covered
3.01
Kopf
Light barrier at the print-
head raising mechanism
0
Printhead in economy position
(raised)
254
Printhead in print position
(lowered)
[Tab. 10] Testbedingungen für Sensoren, die an eine der Endstufen-Platinen angeschlossen werden.
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...