06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
98
5. Remove the power supply.
6. (RH only) Unscrew the fixing bracket fromt
the power supply.
Assembly
To assemble the device, follow the steps in
the reverse order. While doing so, pay at-
tention to:
Connect the power supply as shown in
Screw the PE cable [211A] to the ma-
chine housing; assemble the parts in the
following order to the threaded bolt: Serra-
ted lock washer - Eyelet - Serrated lock
washer - Nut.
After assembling, check the machine
according to the regulations which are rele-
vant in your country
1
.
Further information about power supplies
can be found in topic section
, "Power supplies".
WARNING!
Hazard caused by dangerous
contact voltage!
Attach the PE cable to the machine
housing.
After assembling, check the machi-
ne according to the regulations
which are relevant in your
country
1) Relevant in Germany: DIN VDE 701-702 about "repair, modi-
fication and inspection of electrical equipment"
[210] Connecting the power supply:
A
CPU data (-->CN 403)
B
Remote on-off switch
C
Printhead
D
CPU supply voltage 5 V (-->CN 1401)
E
USI + CPU board
F
CPU supply voltage 24 V (-->CN 1400)
G
Output stages
H
AI
[211] PE-cable (A) attached to the housing.
B C
D E
G
H
A
F
A
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...