03/10 Rev. 5.04-01
USER MANUAL
Mounting & Setting
LA-BO
8
Parameter settings on the ALS 20x/256
Firmware 1.10
Firmware 1.33
(Standard signal
interface)
Firmware 1.33
(Applicator
interface)
¯
The
APPLICATOR PARA
menu appears, if the optional applicator interface is
installed.
Menu
Parameter
Value
MACHINE SETUP
Act. Apl. Interf.
„Int. appl. Interf.“: Activates the internal
applicator interface.
„Ext. appl. Interf.“: Appears only if the
optional applicator interface is installed.
LABEL SETUP
Lab. stop offset
19.0 mm (also depending on distance of
label sensor to disp. edge, label must be
entirely dispensed)
APPLICATOR PARA
Applicator type
ASA
Apply mode
„After start sig.“
(preferred setting for maximum output
capacity)
Blow on time
60 ms
[Tab. 1]
The parameter settings required for operating the LA-BO applicator on an
ALS 20x/256 (Labeller firmware version: 1.10).
Menu
Parameter
Value
LABEL SETUP
Lab. stop offset
19.0 mm (also depending on distance of
label sensor to disp. edge, label must be
entirely dispensed)
SIGNAL INTERFACE Interface mode
„Applicator int.“
SIGNAL INTERFACE
> APPLICATOR INT.
Applicator type
ASA
Apply mode
„After start sig.“
(preferred setting for maximum output
capacity)
Blow on time
60 ms
[Tab. 2]
The parameter settings required for operating the LA-BO applicator on an
ALS 20x/256 (Labeller firmware version: 1.33).
Menu
Parameter
Value
LABEL SETUP
Lab. stop offset
19.0 mm (also depending on distance of
label sensor to disp. edge, label must be
entirely dispensed)
APPLICATOR PARA
Applicator type
ASA
Apply mode
„After start sig.“
(preferred setting for maximum output
capacity)
Blow on time
60 ms
[Tab. 3]
The parameter settings required for operating the LA-BO applicator on an
ALS 20x/256 (Labeller firmware version: 1.33).