Operating Manual
LA-BO
6.
Connect the LA-BO to the service unit. Connect the compressed air line to the service unit. For
more information, see chapter
on page 25.
Adjustment/Setting
Adjusting the dispensing edge to the vacuum grid
After fitting the applicator, the position of the vacuum grid of the applicator in relation to the dispens-
ing edge must be verified and adjusted if necessary. When viewed from the side, the bottom surface of
the vacuum grid must be slightly below and in front of the dispensing edge (figure below).
39 mm
Fig. 6: Position of dispensing edge to vacuum grid.
As a guideline, the vacuum grid surface should be positioned approximately 1 mm
below
the center of
the dispensing edge.
To adjust:
► Adjust the position of the applicator so that the lower edge of the mounting block on the rods is 39
mm above the black end piece (picture above).
Standard signal interface - parameter settings
The parameter settings required for operating the LA-BO applicator controlled by the
standard signal
interface
:
Menu
Parameter
Setting
LABEL SETUP
Lab. stop offset
19.0 mm (also depending on distance of label sensor
to disp. edge, label must be entirely dispensed)
SIGNAL INTERFACE
Interface mode
„Applic. signals“
Apply mode
„After start sig.“
(preferred setting for maximum output capacity)
SIGNAL INTERFACE
>APPLIC. SIGNALS
Blow on time
60 ms
Edition 05 - 08/2022
19
Startup
Mounting & Setting on ALS/XLS 2xx, ALS 306 or ALX 73x