6.2 Digging with a known starting level
Set the height difference between the starting point and the target level as the starting level (3.00
m in this example) in “Main menu” → “Starting level”. Use the arrow keys to set the desired height
and press “Save”. You can also set the starting level by pressing and holding the “0.0” button in the
measurement mode for three seconds.
Move the bucket to a stake or other reference point. Zero the measurement value by pressing the
“0.0” button. The starting level (“3.00” in this example) appears on the screen (Figure 25).
During digging, the value decreases. Target level has been reached when the reading is “0.00”
(Figure 26).
6.3 Depth measurement, moving the excavator
When moving the excavator, its altitude always changes. To maintain the original reference level,
the bucket must be taken to a certain reference point before and after moving the machine, or a
rotating laser has to be used.
Note
When moving the excavator, it is advised to use the laser to achieve the best
possible accuracy (see chapter 6.3.1).
Xsite EASY | User manual | Page 32 of 52
Figure 25. Zeroing the reading on a stake
Figure 26. Digging towards zero