2.4.2 Depth and distance accuracy test 2
Below are the instructions for carrying out accuracy test 2 (Figure 4)
1. Place the bucket on the ground and zero the measurement reading.
2. Move the bucket and use a tape measure to measure the depth and distance difference
between the bucket measuring point and the zeroed point.
3. The system should indicate the same readings with a ±1 cm accuracy tolerance.
2.4.3 Tilting bucket accuracy test
When using the tilt function, test the accuracy of the bucket edges (Figure 5).
1. Straighten the tilt rotator.
2. Switch the measuring point to centre and select a measurement mode showing depth and
distance.
3. Align the bucket blade to a horizontal level and move the centre of the bucket to the
reference point. Zero depth and distance readings by pressing the “0.0” button.
4. Tilt the bucket and put the left corner on the reference point. Change the measuring point
to the lowest corner.
5. Depth and distance readings should be “0.00” in every position (make sure that the
correct measuring point is in use).
6. Repeat this accuracy test with the other corner of the bucket.
7. If the accuracy is worse than
±
2 cm, carry out tilt bucket calibration (chapter 5.3).