SLMKII MIDI Programmer’s Reference
Page 13 of 33
Echo CC Message Response:
BF
63
00-7Fh
This command was originally used by the Reason LUA script to simulate an externally
triggered event. All it does is to echo back the received CC message and value.
Parameter Request Response:
BF
67
RR
This CC is sent to the PC in response to a Parameter Request (RR) sent to unit.
Currently there are two Parameter Request values that can be sent to the SLMKII:
BF
67
00
Request the Unit-Product-Type
BF
67
01
*Request the Transport-Lock State
*Not implemented on the RZeroSL
A Request for the Unit-Product-Type responds as follows:
BF
67
00
If unit is a RemoteSL/SLMKII
BF
67
01
If unit is a ZeroSL/ZeroMKII
BF
67
02
If unit is a Compact
A Request for the Transport-Lock status responds as follows:
BF
4F
00
Transport-Lock is OFF
BF
4F
01
Transport-Lock is ON
Off/OnLine CC Message from the SLMKII:
BF
6B
00
The last special-template has been unloaded
BF
6B
01
A special-template has been Loaded
This command supplement s the off/online sysex commands, and is sent to the
current control-ports.